Background: We sought to incorporate electron beam tomography-derived calcium scores in a model for prediction of angiographically significant coronary artery disease (CAD). Such a model could greatly facilitate clinical triage in symptomatic patients with no known CAD.
Methods And Results: We examined 1851 patients with suspected CAD who underwent coronary angiography for clinical indications. An electron beam tomographic scan was performed in all patients. Total per-patient calcium scores and separate scores for the major coronary arteries were added to logistic regression models to calculate a posterior probability of the severity and extent of angiographic disease. These models were designed to be continuous, adjusted for age and sex, corrected for verification bias, and independently validated in terms of their incremental diagnostic accuracy. The overall sensitivity was 95%, and specificity was 66% for coronary calcium to predict obstructive disease on angiography. With calcium scores >20, >80, and >100, the sensitivity to predict stenosis decreased to 90%, 79%, and 76%, whereas the specificity increased to 58%, 72%, and 75%, respectively. The logistic regression model exhibited excellent discrimination (receiver operating characteristic curve area, 0.842+/-0.023) and calibration (chi2 goodness of fit, 8.95; P=0.442).
Conclusions: Electron beam tomographic calcium scanning provides incremental and independent power in predicting the severity and extent of angiographically significant CAD in symptomatic patients, in conjunction with pretest probability of disease. This algorithm is most useful when applied to an intermediate-risk population.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1161/01.cir.0000014483.43921.8c | DOI Listing |
Volume electron microscopy (vEM) enables biologists to visualize nanoscale 3D ultrastructure of entire eukaryotic cells and tissues prepared by heavy atom staining and plastic embedding. The highest resolution vEM technique is focused ion-beam scanning electron microscopy (FIB-SEM), which provides nearly isotropic (~5-10 nm) spatial resolution at fluences of > 10,000 e /nm . However, it is not clear how such high resolution is achievable because serial block-face (SBF) SEM, which incorporates an in-situ ultramicrotome instead of a Ga FIB beam, results in radiation-induced collapse of similar specimen blocks at fluences of only ~20 e /nm .
View Article and Find Full Text PDFFood Sci Nutr
January 2025
Department of Food Science and Technology, Faculty of Technical and Engineering University of Science and Arts of Yazd Yazd Iran.
In this study, minced turkey meat samples were subjected to electron-beam irradiation with dosages of 0, 1.5, 3, and 5 kGy, and then microbial (mesophilic and psychrotrophic bacteria), physiochemical (pH, water activity [a], thiobarbituric acid reactive substances [TBARS], and peroxide value [PV]), and sensory (color, odor, texture, and overall acceptability) analyses were performed at 0 and 6 months of freezing storage (-18°C). Results showed that by 5 kGy irradiation and freezing treatments, the counts of psychrotrophic and mesophilic bacteria reduced remarkably ( < 0.
View Article and Find Full Text PDFMicroscopy (Oxf)
January 2025
Department of Materials Physics, Graduate School of Engineering, Nagoya University, Chikusa-ku, Nagoya 464-8603, Japan.
The distribution of dopants in host crystals significantly influences the chemical and electronic properties of materials. Therefore, determining this distribution is crucial for optimizing material performance. The previously developed statistical ALCHEMI (St-ALCHEMI), an extension of the atom-location by channeling-enhanced microanalysis (ALCHEMI) technique, utilizes variations in electron channeling based on the beam direction relative to the crystal orientation.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Zhejiang Key Laboratory of 3D Micro/Nano Fabrication and Characterization, School of Engineering, Westlake University, Hangzhou, Zhejiang 310030, China.
High-energy electron beam exposure is generally recognized as the standard for achieving high-precision nanofabrication. Low-energy electron beam exposure techniques offer advantages in 3D manufacturing; however, they have received limited attention in traditional processes due to precision limitations and insufficient exposure, leading to an underestimation of their potential. In this article, we introduce a nanofabrication strategy using low-energy electrons in ice-assisted electron-beam lithography (iEBL) alleviating the compatibility issue between resolution and quasi-3D manufacturing.
View Article and Find Full Text PDFJ Stomatol Oral Maxillofac Surg
January 2025
Department of Stomatology, the Fifth Affiliated Hospital of Zunyi Medical University, Zhuhai 519090, China. Electronic address:
Objective: To investigate the reparative effect of hypoxia pretreated hAMSCs on radiation-induced damage to salivary gland function in mice.
Methods: hAMSCs were separated from human amniotic tissues by mechanical and enzymatic digestion methods and a 15 Gy electron beam was used to locally irradiate the neck of mouse to create a salivary gland injury model. The mouse models were randomly divided into four groups: control group, IR+PBS group, IR+Nor group and IR+HP group.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!