Conductivity (CD)-based dialysance measurements precisely match urea dialysance with <5% difference. For measurement, a CD step-profile is applied by increasing dialysate inlet CD at time t0 for 10% above baseline and lasting for 2-5 min until t1, followed by a decrease to -4% until t2 and a final return to baseline, meanwhile recording dialysate CD at filter inlet (cdi) and outlet (cdo), dialysate flow (Qd), and ultrafiltration (UF)-rate (Qf). Electrolytic dialysance (KeCn) is calculated by KeCnI,J = (1 -[cdoI-cdoJ]/[cdiI-cdiJ])(Qd+Qf) with time index I not = J. The combinations in I,J are not equivalent: KeCn0,1 < KeCn1,2 < KeCn0,2. Each difference is 2% to 5%, and a difference versus urea clearance remains. An in vivo on-line clearance study (10 patients, 100 dialysis sessions, 265 measurements) with automatic electrolytical dialysance measurements and permanent data recording was conducted. Two methods were applied: a CD step-profile and a significantly smaller, dynamic CD bolus. Both were compared to laboratory reference of urea clearance. Reference Kt/V has been calculated using equilibrated single-pool methods and direct quantification. Urea generation was ignored. The results are as follows. The reference blood-side urea clearance was 164.0 +/- 11.8 ml/min, n = 265. The mean errors of the ionic dialysance results are KeCn0,1: -9.1 +/- 4.8%, n = 250; KeCn1,2: -5.6 +/- 4.4%, n = 250; KeCn0,2: 6.8 +/- 7.7%, n = 250; KeCnBolus: 0.1 +/- 4.8%, n = 162. The KeCnI,J error is urea distribution volume related. Kt/V comparison to equilibrated single pool is as follows: KeCn1,2t/V: 0.0 +/- 5.0% (r = 0.96, n = 45); KeCnBolust/V: 5.3 +/- 3.9% (r = 0.98, n = 44). The comparison to direct quantification is as follows: KeCn1,2t/V: -2 +/- 6.4% (r = 0.95, n = 68); KeCnBolust/V: 3.2 +/- 6.3% (r = 0.95, n = 66). V could roughly be measured. Dialysance measured by the step-function method was dependent on sodium load and distribution volume while the CD-bolus dialysance was not. Errors are generated by measurement-induced sodium shift that is sufficient even to estimate urea distribution volume. For dialysance measurements, small dynamic CD boli are preferable to stable step functions.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1525-1594.2002.06817.xDOI Listing

Publication Analysis

Top Keywords

ionic dialysance
4
dialysance measurement
4
measurement urea
4
urea distribution
4
distribution volume
4
volume dependent
4
dependent approach
4
approach better
4
better conductivity
4
conductivity cd-based
4

Similar Publications

Developing hydrogels with high conductivity and toughness a facile strategy is important yet challenging. Herein, we proposed a new strategy to develop conductive hydrogels by growing metal dendrites. Water-soluble Sn ions were soaked into the gel and then converted to Sn dendrites an electrochemical reaction; the excessive Sn ions were finally removed by water dialysis, accompanied by dramatic shrinkage of the gel.

View Article and Find Full Text PDF

Copper-containing industrial wastewater, characterized by strong acidity, high ionic strength, and various competing metals, presents significant challenges for Cu(II) recovery. To address these issues, an electric field-enhanced ultrafiltration process was developed, assisted with a functional polyelectrolyte with high selectivity for Cu(II). The polyelectrolyte, termed PPEI, was synthesized by grafting picolyl groups onto polyethyleneimine (PEI), enhancing its affinity for Cu(II).

View Article and Find Full Text PDF

Developing a Simple and Feasible Process for the Crude Extraction of Livetins and Phosvitin from Egg Yolk.

Foods

December 2024

State Key Laboratory of Food Science and Resources, School of Food Science and Technology, Jiangnan University, Wuxi 214122, China.

Due to imbalanced demand favoring egg whites, the egg industry faces a surplus of egg yolk, limiting overall growth. This study designed a feasible process for the crude extraction of livetins and phosvitin (PV) and revealed the related separation mechanisms. Our method utilized a 1:9 egg yolk dilution at pH 6.

View Article and Find Full Text PDF

Peritoneal dialysis (PD) is an increasingly needed, life-maintaining kidney replacement therapy; efficient solute transport is critical for patient outcome. While the role of peritoneal perfusion on solute transport in PD has been described, the role of cellular barriers is uncertain, the mesothelium has been considered irrelevant. We calculated peritoneal blood microvascular endothelial (BESA) to mesothelial surface area (MSA) ratio in human peritonea in health, chronic kidney disease, and on PD, and performed molecular transport related gene profiling and single molecule localization microscopy in two mesothelial (MC) and two endothelial cell lines (EC).

View Article and Find Full Text PDF
Article Synopsis
  • In this study, BC/PEC composite hydrogels were created for use as an electrode separator by blending bacterial cellulose (BC) with a polyelectrolyte complex (PEC) for enhanced properties.
  • The resulting hydrogel was improved in mechanical strength and thermal stability by incorporating a cross-linking agent, glutaraldehyde, into the BC framework and controlling the formation of the PEC hydrogel.
  • The BC-GA/PEC composite demonstrated lower electrolyte permeability and effective charge-discharge cycling performance in zinc batteries, showing less corrosion on the zinc anode and a reduction in dendrite growth, indicating its potential as a superior alternative to traditional liquid electrolyte separators.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!