This study was undertaken to determine whether carotid intima-media thickness can predict complex aortic atherosclerosis. A retrospective review was conducted of 64 consecutive patients who underwent transesophageal echocardiography and carotid ultrasonography for evaluation of recent ischemic stroke at MCP Hahnemann University, Medical College of Pennsylvania Hospital between January 1, 1999, and December 31, 1999. The mean age was 65+/-14 years and 59% of the patients were women. Thirty-nine patients (61%) had carotid atherosclerosis (defined as an intima-media thickness > or =1 mm) and seven patients (11%) had complex aortic atherosclerosis (defined as the presence of protruding atheroma > or =4 mm thick, mobile atherosclerotic debris, or plaque ulceration in any aortic segment by transesophageal echocardiography). Compared to patients without complex aortic atherosclerosis, patients with complex aortic atherosclerosis were more likely to have hypercholesterolemia (19% vs 57%, p = 0.05) and a carotid intima-media thickness of 2 mm or greater (35% vs 86%, p = 0.02). A carotid intima-media thickness of 2 mm or more had 86% sensitivity, 65% specificity, 23% positive predictive value, 97% negative predictive value, 2.5 positive likelihood ratio, and 0.22 negative likelihood ratio for the diagnosis of complex aortic atherosclerosis. Carotid intimamedia thickness measurement can be used to noninvasively estimate the probability of complex aortic atherosclerosis. A carotid intima-media thickness less than 2 mm makes complex aortic atherosclerosis very unlikely.

Download full-text PDF

Source
http://dx.doi.org/10.1177/000331970205300209DOI Listing

Publication Analysis

Top Keywords

complex aortic
32
aortic atherosclerosis
32
intima-media thickness
24
carotid intima-media
16
aortic
9
atherosclerosis
9
complex
8
thickness complex
8
atherosclerosis patients
8
transesophageal echocardiography
8

Similar Publications

Objective: As aneurysmal disease is progressive, proximal disease progression and para-anastomotic aneurysms are complications experienced after open infrarenal abdominal aortic aneurysm repair (AAA). As such, fenestrated or branched endovascular repair (F/BEVAR) may be indicated in these patients. Data describing fenestrated endovascular aneurysm repair after prior open repair are limited to institutional databases.

View Article and Find Full Text PDF

Objective: Medicare insures over 65 million Americans and is a primary driver of private insurance reimbursement rates. However, public data shows Medicare reimbursement for comparatively complex procedures such as aortic aneurysm repair is disproportionate. Medicare reimbursement rates are multifactorial and highly localized, yet little is known about nationwide trends.

View Article and Find Full Text PDF

Atrial fibrillation (AF) is common and its treatment is complex. The new European guidelines emphasize a patient-centered approach, considering the risk factors that contribute to AF and their management in primary and secondary prevention. Recent advances in electrophysiology include the development of new ablation techniques and the implantation of a leadless bicameral pacemaker.

View Article and Find Full Text PDF

Introduction: Pelvic fractures often result in life-threatening bleeding and hemodynamic instability. Resuscitative endovascular balloon occlusion of the aorta (REBOA) has emerged as a promising strategy for patients with severe pelvic fractures, facilitating subsequent hemostatic interventions. Transcatheter arterial embolization (TAE) is a well-established procedure for managing pelvic fractures accompanied by hemorrhage.

View Article and Find Full Text PDF

Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).

Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!