A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[A methodological study of measuring quantitatively turbulent shear stree downstream of mitral stenosis in vivo using Doppler echocardiography]. | LitMetric

In order to establish a method for measuring quantitatively turbulent shear stress (TSS) downstream of mitral stenosis in vivo based on Doppler echocardiography and computer-aided image analysis, we used doppler echocardiography to record the spectrum of flow velocity downstream of mitral valve at several locations in normal persons and in patients with mitral stenosis. With the computer-aided analysis of spectrum images, the magnitude of TSS was measured at the locations. The results demonstrate that no matter how severe the mitral stenosis is, the TSS and relative turbulent intensity(Irel) at the central locations of jet are lower than those at the marginal ones. A significant difference in the quantitative items of TSS, Irel and flow field uniformity between normal persons and patients with varying-degree of mitral stenosis was noticed (P < 0.05). There was a significant correlation between these items and effective orifice area (EOA), and we found that the smaller EOA is, the more severe the extent of stenosis is and the greater the magnitude of both TSS and Irel are, and that the highest magnitude of TSS is focused on the marginal area of jet. These results indicate that there is an obvious correlation between TSS(measured by Doppler echocardiography combined with computer-aided image analysis) and flow field uniformity. They can coincidently reveal the hemodynamic changes resulting from mitral stenosis of varied severeness, implying that our method could exactly depict the magnitude of TSS downstream of mitral stenosis in vivo and is non-invasive and good for anti-disturbance. The method can be used to analyze quantitatively TSS in the flow field of heart valve in patients with valvular diseases.

Download full-text PDF

Source

Publication Analysis

Top Keywords

mitral stenosis
28
downstream mitral
16
magnitude tss
16
stenosis vivo
12
doppler echocardiography
12
flow field
12
measuring quantitatively
8
quantitatively turbulent
8
turbulent shear
8
mitral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!