This study examined the effect of washer usage on initial pedicle screw fixation and on the salvage of replaced pedicle screws, and the effect of minor adjustments of pedicle screws on insertional torque. Titanium, nontapered pedicle screws (6.5-mm in diameter and 35-mm in length) from one manufacturer and custom-made 5-mm washers were used in the fixation of porcine lumbar spines. Insertional torque was measured with an electronic torque screwdriver and failure strength was determined by straight pullout of the screws using an MTS machine. Initial insertional torque values were significantly greater in pedicle screws placed with washers compared with screws placed without washers. When the screw placed without a washer was salvaged with the addition of a washer, a significant increase in insertional torque resulted. Pullout testing failed to show a significant difference between the screws that were placed with washers and the screws that were placed without washers. In the second part of the experiment, there was a significant decrease in insertional torque after backing out the screw as little as 90 degrees. This current study showed that (1) washers significantly increase the insertional torque of pedicle screws; (2) screws placed without a washer can be salvaged and replaced with a washer, which results in significantly increased insertional torque; and (3) backing out a pedicle screw 90 degrees significantly decreases its insertional torque. Washers can be used with pedicle screws to enhance the initial stability of the screw constructs, and to maximize insertional torque when screws need to be replaced, revised, or adjusted (backed out).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/00003086-200202000-00030 | DOI Listing |
Tissue Eng Regen Med
January 2025
Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul National University Bundang Hospital, 172 Dolma-ro, Bundang-gu, Seongnam-si, Gyeonggi-do, 13620, Republic of Korea.
Background: Traditionally, dental implants require a healing period of 4 to 9 months for osseointegration, with longer recovery times considered when bone grafting is needed. This retrospective study evaluates the clinical efficacy of demineralized dentin matrix (DDM) combined with recombinant human bone morphogenetic protein-2 (rhBMP-2) during dental implant placement to expedite the osseointegration period for early loading.
Methods: Thirty patients (17 male, 13 female; mean age 55.
Biomedicines
December 2024
School of Stomatology, Universidad Privada San Juan Bautista, Lima 15067, Peru.
: This study aimed to evaluate the primary stability, according to the insertion torque value (ITV) and resonance frequency analysis (RFA), of dental implants placed in standardized blocks of bone quality equivalent to type II-A bone, using three surgical undersized protocols of 0.2 mm, 0.5 mm, and 0.
View Article and Find Full Text PDFJ Craniofac Surg
December 2024
Department of Oral and Maxillofacial Surgery, College of Dentistry, King Saud University.
Objectives: This study aimed to evaluate the osseointegration properties of titanium bone implants coated with carob-mediated calcium hydroxide nanoparticles biomechanically, radiographically, and histologically on rabbit tibias.
Material And Methods: Forty coated and forty uncoated titanium alloy bone implants were inserted into 20 New Zealand rabbits; each tibia received 2 implants. The rabbits were sacrificed after 4 or 8 weeks, and samples were retrieved for biomechanical evaluation through removal torque test to assess the bond between implant and bone, radiographic evaluation through microcomputed tomography analysis to compare the bone-to-implant contact percentage and bone volume of the peri-implant area, scanning electron microscopic and histologic evaluation through hematoxylin and eosin stain.
Front Bioeng Biotechnol
December 2024
Department of Spine Surgery, The Affiliated Hospital of Qingdao University, Qindao, China.
Background: Lumbar degenerative diseases are an important factor in disability worldwide, and they are also common among the elderly population. Stand-Alone Oblique Lumbar Interbody Fusion (Stand-Alone OLIF) is a novel surgical approach for treating lumbar degenerative diseases. However, long-term follow-up after surgery has revealed the risk of endplate collapse associated with Stand-Alone OLIF procedures.
View Article and Find Full Text PDFEur J Orthod
December 2024
Department of Dentistry, All India Institute of Medical Sciences, Basni Industrial Area Phase-2, Jodhpur- 342005, Rajasthan, India.