Twenty-seven highly diversified pharmaceutical compounds were used as a test set to evaluate matrix effects from microsomal media on LC/MS analyses. The individual effects of Tris buffer, NADPH and microsomes on ESI response were investigated. Direct flow injection MS/MS analysis, using no sample preparation or HPLC separation, gave an average of 2.2-5-fold matrix suppression in MS response from Tris buffer and NADPH. More polar analytes were affected the greatest. To reduce the loss in response, an automated solid phase extraction (SPE) procedure was developed. A much smaller average matrix effect was observed when samples were prepared using a Waters Oasis HLB 96-well SPE. As little as 1 ml of methanol (MeOH) was sufficient to elute most compounds with more than 80% recovery. Comparable results were obtained by directly injecting a protein-precipitated incubation onto a fast gradient LC separation prior to MS/MS detection. No advantage was seen by using both SPE and a fast LC separation prior to MS/MS analysis.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0731-7085(01)00562-3 | DOI Listing |
ACS Appl Bio Mater
January 2025
Department of Chemical Engineering, Indian Institute of Technology Tirupati, Tirupati, Andhra Pradesh 517619, India.
In the fast-paced quest for early cancer detection, noninvasive screening techniques have emerged as game-changers, offering simple and accessible avenues for precession diagnostics. In line with this, our study highlights the potential of silver nanoparticle-decorated titanium carbide MXene nanosheets (TiC_AgNPs) as an electroactive interface for the noninvasive diagnosis of oral carcinoma based on the prevalence of the salivary biomarker, tumor necrosis factor-α (TNF-α). An in situ reduction was utilized to synthesize the TiC_AgNPs nanohybrid, wherein TiC acts as the reducing agent, and the resulting nanohybrid was subjected to various characterization techniques to examine the optical, structural, and morphological attributes.
View Article and Find Full Text PDFPharmaceuticals (Basel)
December 2024
N. P. Bechtereva Institute of the Human Brain, Russian Academy of Sciences, 197022 St. Petersburg, Russia.
-succinimidyl-[F]fluorobenzoate ([F]SFB) is commonly prepared through a three-step procedure starting from [F]fluoride ion. A number of methods for the single-step radiosynthesis of [F]SFB have been introduced recently, including the radiofluorination of diaryliodonium salts and the Cu-mediated F-fluorination of pinacol aryl boronates and aryl tributyl stannanes, but they still have the drawbacks of lengthy product purification procedures. In the present work, two approaches for the direct labeling of [F]SFB from diaryliodonium (DAI) salt () and pinacol aryl boronate () are evaluated, with a major focus on developing a fast and simple SPE-based purification procedure.
View Article and Find Full Text PDFJ Chromatogr A
January 2025
Fujian Provincial Key Laboratory for Coastal Ecology and Environmental Studies;College of the Environment and Ecology, Xiamen University, Xiamen 361005, PR China. Electronic address:
Magnetic solid phase extraction (MSPE) has been widely employed in the isolation and enrichment of antibiotics in complex matrices because it presents various unique advantages over traditional SPE including simple operation, fast extraction procedure, low cost and eco-friendliness. In recently years, magnetic molecularly imprinted nanoparticles (MMINs) containing highly specific recognition performance have been widely used to specific extraction of antibiotics under the format of MSPE. In this connection, recent advances of MMINs in the analysis of antibiotic residues are reviewed.
View Article and Find Full Text PDFAnal Methods
December 2024
Chemistry Department, College of Science, University of Bahrain, Sakhir 32038, Bahrain.
In this study, a rapid, precise, and targeted electroanalytical method was developed for the trace determination of 4-chlorophenol (4-CP). The study reports the use of cyclic voltammetry (CV) to characterize the electrochemical response of 4-CP and the optimization of differential pulse voltammetry (DPV) settings for its sensitive quantification. Screen-printed carbon electrodes (SPCEs) were selected for the sensitive detection of 4-CP using DPV.
View Article and Find Full Text PDFACS Omega
December 2024
Departamento de Química Analítica, Instituto de Química, Universidade Federal do Rio de Janeiro, Rio de Janeiro 21941-853, Brazil.
One of the main challenges in animal breeding systems is determining estradiol (E2) in livestock samples as simple and minimally invasive as possible, Thus, a nonenzymatic biosensor screen-printed electrode (SPE) was developed by modifying nanohybrid palladium nanoparticles (PdNPs), and carbon dots anchored on a nanosilica particle (PdNPs/C.dots/SiO), denominated SPE/PdNPs/C.dots/SiO, and successfully tested for the direct detection of estradiol in livestock samples.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!