Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Both 2-dimensional echocardiography and myocardial perfusion imaging (MPI) with technetium-99m based agents have been used to identify patients in the emergency department with myocardial infarction (MI). However, the inclusion of small numbers of patients in prior studies limits the accurate assessment of sensitivity of the 2 techniques.
Methods: Gated MPI was used as part of the initial triage process in patients initially considered at low to moderate risk for acute coronary syndromes (no ST elevation or depression). Patients diagnosed with MI also underwent echocardiography. MPI results were considered positive if there was a perfusion defect associated with abnormal wall motion or thickening, and echocardiographic results were considered positive if there were segmental wall motion abnormalities or ejection fraction of less than 40%.
Results: Both tests were performed on 141 patients. The sensitivities for MI for echocardiography (91%; 95% CI, 86%-95%) and MPI (89%; 95% CI, 83%-94%) were similar. Patients who had either negative echocardiographic results (peak creatine kinase level [CK], 325 +/- 206 vs 582 +/- 614 U/L; P =.003) or negative MPI results (peak CK, 313 +/- 227 vs 590 +/- 620 U/L; P =.001) had smaller MIs as estimated with peak CK values. Ejection fraction was highly correlated between the 2 techniques (r = 0.82; P <.001).
Conclusion: Both echocardiography and MPI have a high sensitivity for identifying patients in the emergency department who have MI. False negative studies with either technique were associated with small MIs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1067/mhj.2002.120777 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!