A persistent left superior vena cava (PLSVC) is a rare abnormality that presents a challenge to the implanter. To our knowledge, this is the first case report of implantation of dual-chamber pacemaker via PLSVC utilizing a steerable stylet (the Locater; St. Jude Medical, Inc., Minnetonka, Minnesota) with chronic follow-up showing stable threshold.

Download full-text PDF

Source

Publication Analysis

Top Keywords

implantation dual-chamber
8
dual-chamber pacemaker
8
persistent left
8
left superior
8
superior vena
8
vena cava
8
steerable stylet
8
pacemaker patient
4
patient persistent
4
cava steerable
4

Similar Publications

Reel's syndrome (RS) is an unusual cause of pacemaker lead dislodgement. We present the case of a 59-year-old female patient with Down syndrome (DS) implanted with a dual-chamber endovascular pacemaker due to symptomatic sinus node disfunction, reporting several syncopal episodes in last days and showing abnormal electrical parameters at the 2-months follow-up due to RS. The malfunctioning device was removed and an endocardial leadless pacing system was implanted.

View Article and Find Full Text PDF

Background: Delayed lead perforation is a rare complication of cardiac implantable electronic device (CIED). Clinical presentations range from completely asymptomatic to pericardial tamponade. Surgical lead extraction is recommended and transvenous lead extraction (TLE) with surgical backup is an alternative method.

View Article and Find Full Text PDF

Background: An atrioventricular defibrillator system with a floating atrial dipole (VDD ICD) can provide atrial sensing by a single lead. Our aim was to compare the arrhythmia detection efficacy of VDD ICDs with conventional single- (VVI) and dual-chamber (DDD) defibrillators.

Methods: Data from consecutive patients undergoing ICD implantation were retrospectively analyzed.

View Article and Find Full Text PDF

Introduction: cardiac pacing is the only lifesaving procedure which is effective for major cardiac conduction disorders. In sub-Saharan Africa, few pacemakers are implanted, compared to Western countries. This study aimed to describe the indications for cardiac pacing in four hospitals in Senegal, to evaluate its practical modalities, to identify pacemaker's complications and their predisposing factors and to evaluate the main challenges for cardiac pacing in Senegal.

View Article and Find Full Text PDF

An 83-year-old man underwent dual-chamber pacemaker placement for complete atrioventricular block at another hospital. The active-fixation ventricular lead was positioned on the free wall of the anterior right ventricle. Ventricular pacing failure occurred on the day after pacemaker implantation, and fluoroscopy revealed right ventricular (RV) lead perforation.

View Article and Find Full Text PDF