Purpose: To determine the ablation depths of customized myopic excimer laser photoablations performed to change corneal asphericity after laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK).
Methods: A mathematical model of aspheric myopic corneal laser surgery was generated. The initial corneal surface was modeled as a conic section of apical radius R(1) and asphericity Q(1). The final corneal surface was modeled as a conic section of apical R(2) and asphericity Q(2), where R(2) was calculated from the paraxial optical formula for a given treatment magnitude (D), and Q(2) was the intended final asphericity. The aspheric profile of ablation was defined as the difference between the initial and final corneal profiles for a given optical zone diameter (S), and the maximal depth of ablation was calculated from these equations. Using the Taylor series expansion, an equation was derived that allowed the approximation of the central depth of ablation (t(0)) for various magnitudes of treatment, optical zone diameters, and asphericity. In addition to the Munnerlyn term (M), incorporating Munnerlyn's approximation (-D small middle dot S(2)/3), the equation included an asphericity term (A) and a change of asphericity term (Delta). This formula (t(0) = M + A + Delta) was used to predict the maximal depth of ablation and the limits of customized asphericity treatments in several theoretical situations.
Results: When the initial and final asphericities were identical (no intended change in asphericity; Q(1) = Q(2); Delta = 0), the maximal depth of ablation (t(0) = M + A) increased linearly with the asphericity Q(1). To achieve a more prolate final asphericity (Q(2) < Q(1); dQ < 0; Delta > 0), the maximal depth of ablation (M + A + Delta) was increased. For treatments in which Q(2) was intended to be more oblate than Q(1) (Q(2) > Q(1); dQ > 0; Delta < 0), the maximal depth of ablation was reduced. These effects sharply increased with increasing diameters of the optical zone(s). Similarly, in the case of PRK, the differential increase in epithelial thickness in the center of the cornea compared with the periphery resulted in increased oblateness.
Conclusions: Aspheric profiles of ablation result in varying central depths of ablation. Oblateness of the initial corneal surface, intentional increase in negative asphericity, and enlargement of the optical zone diameter result in deeper central ablations. This may be of clinical importance in planning aspheric profiles of ablation in LASIK procedures to correct spherical aberration without compromising the mechanical integrity of the cornea.
Download full-text PDF |
Source |
---|
J Arrhythm
February 2025
Department of Cardiology Institute of Medicine, University of Tsukuba Tsukuba Japan.
Background/objectives: Very high-power and short-duration (vHPSD) ablation with QDOT MICRO™ facilitates speedy and safe ablation for pulmonary vein isolation. A brief time interval between ablating two neighboring sites with vHPSD may potentially influence the size and geometry of the lesions. This study evaluates lesion formation when delivering adjacent applications using vHPSD at various inter-lesion times (ILTs).
View Article and Find Full Text PDFConventional laser micromachining technologies rely on trial-and-error optimization to obtain precise surface geometry. In this study, we present a laser micromachining setup that enables the preparation of the desired surface geometry without the need for parameter exploration. The setup consists of a laser scanning system, a coaxial imaging system, a paraxial laser line projector, and a three-axis stage.
View Article and Find Full Text PDFBiomaterials
January 2025
Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, 78712, USA. Electronic address:
Direct pacing of the mid myocardium where re-entry originates can be used to prevent ventricular arrhythmias and circumvent the need for painful defibrillation or cardiac ablation. However, there are no pacing electrodes small enough to navigate the coronary veins that cross these culprit scar regions. To address this need, we have developed an injectable ionically conductive hydrogel electrode that can fill the epicardial coronary veins and transform them into flexible electrodes.
View Article and Find Full Text PDFJ Food Sci
January 2025
College of Engineering, Jiangxi Agricultural University, Nanchang, China.
In the intelligent harvesting of eggplant, the lack of in situ identification technology makes it challenging to determine the maturity of purple eggplant fruit. The length of the fruit-setting date can determine when the eggplant is ready to be harvested. This study uses deep learning techniques to predict the date of fruit maturity.
View Article and Find Full Text PDFBMC Bioinformatics
January 2025
School of Information and Artificial Intelligence, Anhui Agricultural University, Changjiang West Road, Hefei, 230036, Anhui, China.
Drug-target interactions (DTIs) are pivotal in drug discovery and development, and their accurate identification can significantly expedite the process. Numerous DTI prediction methods have emerged, yet many fail to fully harness the feature information of drugs and targets or address the issue of feature redundancy. We aim to refine DTI prediction accuracy by eliminating redundant features and capitalizing on the node topological structure to enhance feature extraction.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!