An in vivo study of peripheral nerves in continuity: biomechanical and physiological responses to elongation.

J Orthop Res

The Department of Surgery, The Royal Infirmary of Edinburgh, UK.

Published: March 2002

Using an animal model, the in vivo visco-elastic properties of peripheral nerve in continuity were examined. The nerves were stretched by either 1 cm - Group A (8.8% strain) or 2 cm - Group B (16.1% strain). At constant strain, the stress-relaxation curves were plotted. Maximal relaxation was observed in the first 20 min. After 1 h, the decrease in tensions in Groups A and B were 36.8% and 41.8%, respectively. Throughout this hour and for 30 min after the release of tension, regular recordings of nerve blood flow using laser doppler flowmetry and peak nerve conduction velocity were taken. Nerve blood flow was reduced by similar amounts (Group A, 70%; Group B, 78%) by application of traction. On release, however, Group A displayed a reactive hyperaemia (blood flow 151% starting value) while Group B failed to recover (50% starting value at 30 min). Peak nerve conduction velocity was not significantly altered in Group A in response to traction, whereas in Group B the result was a gradual, but significant reduction in peak velocity to 66% starting value. The lack of correlation between blood flow and peak nerve conduction velocity in these studies suggests that ischaemia is not solely responsible for the increased latency.

Download full-text PDF

Source
http://dx.doi.org/10.1016/S0736-0266(01)00104-8DOI Listing

Publication Analysis

Top Keywords

blood flow
16
peak nerve
12
nerve conduction
12
conduction velocity
12
group
8
nerve blood
8
nerve
6
vivo study
4
study peripheral
4
peripheral nerves
4

Similar Publications

Objectives: The aim of this study was to investigate the risk factors that may cause postoperative otomycosis in patients undergoing Chronic Nonsuppurative Otitis Media (CNSOM) surgery.

Methods: In this retrospective study, 409 out of 523 patients met the inclusion criteria. 44 patients diagnosed with otomycosis CNSOM were analyzed.

View Article and Find Full Text PDF

Hexafluoropropylene Oxide Trimer Acid Is an Unsafe Substitute to Perfluorooctanoic Acid Due to Its Remarkable Liver Accumulation in Mice Disclosed by Comprehensive Toxicokinetic Models.

Environ Sci Technol

January 2025

Key Laboratory of Pollution Processes and Environmental Criteria, Ministry of Education, Tianjin Key Laboratory of Environmental Remediation and Pollution Control, College of Environmental Science and Engineering, Nankai University, Tianjin 300350, P. R. China.

Hexafluoropropylene oxide trimer acid (HFPO-TA, CF(CFOCF(CF))COOH) is widely used as an alternative to perfluorooctanoic acid (PFOA), but whether it is a safe alternative requires further evaluation. In this study, male mice were exposed to three dosages (0.56, 2.

View Article and Find Full Text PDF

Robust preclinical models of asymmetric ventricular loading in late gestation reflecting conditions such as hypoplastic left heart syndrome are lacking. We characterized the morphometry and microvascular function of the hypoplastic left ventricle (LV) and remaining right ventricle (RV) in a sham-controlled late gestation fetal lamb model of impaired left ventricular inflow (ILVI). Singleton fetuses were instrumented at ∼120 days gestational age (dGA; term is ∼147 days) with vascular catheters, an aortic flow probe and a deflated left atrial balloon.

View Article and Find Full Text PDF

The cerebral blood flow response to neuroactivation is reduced in cognitively normal men with β-amyloid accumulation.

Alzheimers Res Ther

January 2025

Functional Imaging Unit, Department of Clinical Physiology and Nuclear Medicine, Copenhagen University Hospital Rigshospitalet, Valdemar Hansens Vej 1-23, Glostrup, 2600, Denmark.

Background: Accumulation of β-amyloid (Aβ) in the brain is a hallmark of Alzheimer's Disease (AD). Cerebral deposition of Aβ initiates deteriorating pathways which eventually can lead to AD. However, the exact mechanisms are not known.

View Article and Find Full Text PDF

Pseudoaneurysm of the descending aorta two decades after aortic coarctation repair: a case report.

J Cardiothorac Surg

January 2025

Department of Cardiovascular Surgery, West China Hospital of Sichuan University, 37# Guoxue Xiang, Chengdu, 610041, Sichuan, China.

Background: Pseudoaneurysm after coarctation of the aorta (CoA) repair is a rare but severe complication. Contributing factors may include infection, hypertension, aortic wall weakness, and turbulent blood flow at the repair site.

Case Presentation: A 35-year-old male presented with recurrent episodes of epistaxis and dizziness was admitted to the emergency department.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!