Purpose: Ultrasound biomicroscopy(UBM) was performed on filtering blebs with laser treatment including laser gonioplasty(GP), laser iridotomy(LI), and YAG laser trabeculopuncture(YLT) after non-penetrating trabeculectomy(NPT). The filtering blebs were grouped into four types, L, H, E and F, and the spaces under the scleral flap were classified into three. La, S, and N.
Cases: In case 1, an F type, an S bleb was not changed despite laser treatment 9 months after NPT. In case 2, YLT was performed twice to release the incarcerated iris. The filtering bleb was changed to the L type, an La bleb. In case 3, an F type, an S bleb was turned into an H type after GP, LI, and YLT. In case 4, GP effectively released peripheral anterior synechia formation and the filtering bleb was kept as an L type, La.
Conclusion: Appropriate laser treatment may be effective in turning a flattened and localized bleb into a good filtering bleb.
Download full-text PDF |
Source |
---|
Eur J Ophthalmol
January 2025
Eye Clinic, Department of Surgical Sciences, University of Cagliari, Cagliari, Italy.
Purpose: To evaluate the incidence and to describe the characteristics of the intrableb pigmentation (IBP) following XEN63 implantation.
Methods: Retrospective case series of three eyes presenting a pigment dispersion in the filtering bleb after a XEN63 implantation for uncontrolled IOP. Demographic, clinical and imaging data were obtained from medical records.
BMJ Case Rep
December 2024
Dr Rajendra Prasad Centre for Ophthalmic Sciences, All India Institute of Medical Sciences, New Delhi, Delhi, India.
Br J Ophthalmol
December 2024
Department of Ophthalmology, University of Bonn, Bonn, Germany.
Background/aims: Bleb characteristics in the area around the plate following glaucoma drainage device (GDD) surgery are difficult to evaluate on slit lamp examination. Ultrasound sonography could be used for more detailed visualisation. The aim of this study was to describe bleb configuration after PAUL glaucoma implant (PGI) surgery and evaluate the possible correlation with intraocular pressure (IOP) in order to derive new markers for evaluating GDD function.
View Article and Find Full Text PDFOphthalmol Ther
December 2024
Department of Ophthalmology, Medical University of Bialystok, M. Sklodowskiej-Curie 24 A STR, 15-276, Bialystok, Poland.
Glaucoma and cataract often coexist. Patients with both conditions who qualify for surgical treatment may undergo either a combined surgical procedure or sequential treatments such as cataract surgery followed by an antiglaucoma procedure. A combined procedure with phacoemulsification is related to an increased risk of fibrosis of the filtering bleb; however, it is a rational approach for patients with high intraocular pressure and clinically significant lens opacification.
View Article and Find Full Text PDFEur J Ophthalmol
December 2024
Ophthalmology Glaucoma Department, Fundación Oftalmológica Médica de la Comunidad Valenciana (FOM), Valencia, Spain.
Introduction: To present a novel surgical technique for the treatment of a steep-walled filtering bleb following an Ahmed glaucoma valve implant. The primary aim was to alleviate the patient's discomfort and address associated corneal thinning, complications that can arise from this condition.
Methods: Case report and surgical technique.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!