A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Noise attenuation characteristics of a foam type earplug measured using a dummy head. | LitMetric

Noise attenuation characteristics of a foam type earplug measured using a dummy head.

J UOEH

Department of Health Policy and Management, Institute of Industrial Ecological Sciences, University of Occupational and Environmental Health, Yahatanishi-ku, Kitakyushu 807-8555, Japan.

Published: March 2002

The attenuation characteristics of the earplug using a dummy head (KEMAR; Knowles Electronics Manikin for Acoustic Research) were measured, when it was exposed to pure tones or broadband noises at three different sound pressure levels (SPLs) of 70, 80 and 90 dB SPL in the 'wide frequency range from 250 to 20 k Hz. We ascertained the satisfactory capacity of noise attenuation except for from 10 k to 14 k Hz. The noise attenuation level increased with frequency until 2 k Hz, became almost constant until 8 k Hz, then decreased at around 10 k to 14 k Hz, and recovered in the range from 16 k to 20 k Hz. The frequency characteristics were identical among three different sound pressure levels and almost identical between pure tones and broadband noises. The change of frequency characteristics affected by the depth of the earplug that was inserted into the artificial ear canal of the KEMAR was also investigated. Measured sound pressure level by the builetin microphone in the KEMAR revealed a region in which the measured sound pressure levels were relatively higher around 10 k Hz. The frequency of the region moved higher when the earplug was inserted more deeply. Therefore it was considered that this phenomenon was related to the resonance frequency of the cylinder-like cavity made between the end section of the earplug and the diaphragm of the built-in microphone.

Download full-text PDF

Source
http://dx.doi.org/10.7888/juoeh.24.11DOI Listing

Publication Analysis

Top Keywords

sound pressure
16
noise attenuation
12
pressure levels
12
attenuation characteristics
8
dummy head
8
pure tones
8
tones broadband
8
broadband noises
8
three sound
8
frequency characteristics
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!