[Precision and reliability of Orbscan and ultrasonic pachymetry].

J Fr Ophtalmol

Pôle St Antoine/CHNO des Quinze-Vingts, 28, rue de Charenton, 75571 Paris.

Published: November 2001

Purpose: To compare the accuracy and reproducibility of the orbscan pachymetry and ultrasonic pachymetry in the normal eye and in the penetrating keratoplasty eye.

Methods: Pachymetric measurements were assessed in 50 eyes of 25 normal patients and 50 eyes of 48 patients who had undergone penetrating keratoplasty using both Orbscan II and ultrasonic pachymetry (Tomey SP-2000). For each eye, 2 successive measures were recorded with both instruments. For both devices, the default setting was used. Orbscan pachymetry maps were divided into 5 groups using a modification of Liu's classification.

Results: Orbscan pachymetry strongly correlated with ultrasonic pachymetry (rs = 0.91; p < 0.001). Ultrasonic pachymetry values and Orbscan pachymetry values showed no significant differences in the normal group (respectively, 557 microns +/- 36 and 555 microns +/- 34; p > 0.05). Ultrasonic pachymetry values and orbscan pachymetry values were significantly different in the penetrating keratoplasty group (respectively, 571 microns +/- 52 and 550 microns +/- 54; p < 0.001). The best value for the acoustic factor for Orbscan pachymetry in the penetrating keratoplasty group was 0.89. Ultrasonic pachymetry reproducibility and Orbscan pachymetry reproducibility were not significantly different (0.86% +/- 0.61 v. 0.67% +/- 0.63; p = 0.13 in the normal group; 1.22% +/- 0.81 v. 1.23% +/- 1.13; p = 0.92, in the penetrating keratoplasty group). Both pachymetry methods showed less reproducibility in the penetrating keratoplasty group than in the normal group (p < 0.02). Thinnest point localization was significantly different in both groups (p < 0.001). In 66% of the normal group, the thinnest point of the cornea was located in inferotemporal quadrant. This point was located at an average of 0.63 +/- 0.25 mm from the visual axis in the normal group and 1.60 +/- 0.81 mm in the penetrating keratoplasty group (p < 0.001). Whereas "Centered round" (40%) and "centered oval" (34%) were the most common patterns in the normal group, "decentered oval" (40%) and "irregular" (30%) were more frequent in the penetrating keratoplasty group (p < 0.001).

Conclusion: Orbscan pachymetry strongly correlated with ultrasonic pachymetry. Reproducibility of both methods is excellent and not significantly different. Thinnest point localization and pachymetric map classification are significantly different in normal eyes and in penetrating keratoplasty eyes.

Download full-text PDF

Source

Publication Analysis

Top Keywords

penetrating keratoplasty
36
orbscan pachymetry
32
ultrasonic pachymetry
28
normal group
24
keratoplasty group
24
pachymetry
16
pachymetry values
16
microns +/-
16
group
12
pachymetry reproducibility
12

Similar Publications

: Clinically inactive corneal scars have repeatedly been shown to exhibit histological inflammation. This study aimed to evaluate the degree of histological inflammation in clinically inactive corneal scars of different origins and its correlation with graft rejection and failure following penetrating keratoplasty. : The study included 205 primary corneal explants with clinically inactive central scars resulting from herpes simplex virus keratitis (HSV, = 55), keratoconus ( = 39), mechanical trauma ( = 27), scrophulosa ( = 22) or other/unknown causes ( = 62).

View Article and Find Full Text PDF

: The aim of this study was to evaluate the effect of a surgical technique for managing post-penetrating keratoplasty (PK) ectasia complicated by late endothelial failure (LEF). : A single-center pilot case series was conducted regarding consecutive patients affected by post-PK ectasia with late graft failure. Using a microkeratome, a single donor cornea was dissected to prepare a two-piece graft, comprising a larger anterior lamella made up of anterior stroma and a smaller posterior lamella made up of posterior stroma, Descemet's membrane, and endothelium.

View Article and Find Full Text PDF

In Vivo Confocal Microscopy Findings in Corneal Stromal Dystrophies.

Diagnostics (Basel)

January 2025

Department of Ophthalmology, Faculty of Medicine, Selcuk University, Konya 42130, Türkiye.

In this study, we aim to evaluate in vivo confocal microscopy (IVCM) findings of corneal stromal dystrophies (CSDs) including granular, macular and lattice corneal dystrophy that can be used for differential diagnosis and monitoring recurrences after surgical interventions. : Patients diagnosed with CSD who were followed-up in the cornea and ocular surface unit were included in this study. IVCM was performed using the Heidelberg Retina Tomograph 3, Rostock Cornea Module (Heidelberg Engineering, Germany) and anterior segment optical coherence tomography (AS-OCT) imaging was performed using the Spectralis OCT (Heidelberg Engineering, Germany).

View Article and Find Full Text PDF

Background: The study aimed to review the etiology of corneal blindness and investigate the relative risk of corneal graft rejection (CGR) in the southern Liaoning region.

Methods: The clinical records of 359 patients (394 eyes) who underwent corneal transplantation at the Department of Keratoconus of the Third People's Hospital of Dalian from January 2019 to December 2023 were retrospectively analyzed. The data included patients' age, gender, occupation, diagnosis, surgical procedure, postoperative immune rejection, and neovascularization.

View Article and Find Full Text PDF

Purpose: To analyze the outcomes of corneal transplantation procedures over a 13-year period at Farabi Eye Hospital, Tehran, Iran, to identify trends and determinants influencing the frequency and success of primary and re-transplantations.

Methods: Utilizing a comprehensive dataset from the hospital's Hospital Information System, the study reviewed the records of 8,378 patients who underwent corneal transplants between 2009 and 2022. This analysis included demographic information, surgical details, and follow-up data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!