We propose and theoretically analyze a new approach for generating and shaping 1-fs pulses. It combines the ideas of strong-field molecular optics and optimal control to manipulate light generation in a pump-probe Raman regime. Flexible phase control over the generated spectrum of about 3 eV width is achieved by controlling the input pulses and maximizing the coherence of medium excitation by adiabatically aligning molecules in the medium with a specially shaped pump pulse. The generated pulse is optimized for an output window, precompensating for its dispersion to all orders.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.88.103901DOI Listing

Publication Analysis

Top Keywords

1-fs pulses
8
generation single
4
single dispersion
4
dispersion precompensated
4
precompensated 1-fs
4
pulses shaped-pulse
4
shaped-pulse optimized
4
optimized high-order
4
high-order stimulated
4
stimulated raman
4

Similar Publications

Direct coupling of light to valley current.

Nat Commun

August 2024

Max-Born-Institut für Nichtlineare Optik und Kurzzeitspektroskopie, Max-Born-Strasse 2A, 12489, Berlin, Germany.

The coupling of circularly polarized light to local band structure extrema ("valleys") in two dimensional semiconductors promises a new electronics based on the valley degree of freedom. Such pulses, however, couple only to valley charge and not to the valley current, precluding lightwave manipulation of this second vital element of valleytronic devices. Contradicting this established wisdom, we show that the few cycle limit of circularly polarized light is imbued with an emergent vectorial character that allows direct coupling to the valley current.

View Article and Find Full Text PDF

We demonstrate cascaded nonlinear pulse compression of a Yb-doped fiber laser. The system is based on two pulse compression stages with bare single-mode fiber (SMF) and ultra-high NA (UHNA) fibers combined with two pairs of chirped mirrors. The 10 nJ, 110 fs input pulses are compressed down to 9.

View Article and Find Full Text PDF

To fully exploit ultra-short X-ray pulse durations routinely available at X-ray free-electron lasers to follow out-of-equilibrium dynamics, inherent arrival time fluctuations of the X-ray pulse with an external perturbing laser pulse need to be measured. In this work, two methods of arrival time measurement were compared to measure the arrival time jitter of hard X-ray pulses. The methods were photoelectron streaking by a THz field and a transient refractive index change of a semiconductor.

View Article and Find Full Text PDF

Higher harmonics and supercontinuum generated from the Kerr response time in different states of matter from a universal electromagnetic model.

Sci Rep

September 2023

Institute for Ultrafast Spectroscopy and Lasers-Physics Department, The City College of New York, 160 Convent Avenue, New York, NY, 10031, USA.

There is a need for a universal model to describe higher harmonic generation (HHG) in different states of matter. Based on an electromagnetic model (EM), the generation of odd higher harmonic (HHG) and supercontinuum (SC) from intense fs and ps pulses for visible, NIR, and MIR lasers is simulated based on the parameters from experimental observation. HHG and SC depend critically on the different Kerr material response times τ from the ultrafast on the order of 100 as for electronic cloud distortion to fast ~ 10 fs from plasma and molecular redistribution and to the slower picoseconds rotational and vibrational molecular processes.

View Article and Find Full Text PDF

We report on the complete temporal characterization of ultrashort pulses, generated by resonant dispersive wave emission in gas-filled hollow-capillary fibers, with energy in the microjoule range and continuously tunable from the deep-ultraviolet to the ultraviolet. Temporal characterization of such ultrabroad pulses, particularly challenging in this spectral region, was performed using an all-in-vacuum setup for self-diffraction frequency resolved optical gating (SD-FROG). Sub-3-fs pulses were measured, tunable from 250 nm to 350 nm, with a minimum pulse duration of 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!