The effects of a Micelle Encapsulator Fire Suppression Agent (F-500, Hazard Control Technologies Inc., Fayetteville, Georgia) on the routine analysis of fire debris samples by Gas Chromatography (GC) were studied. When mixed with water the product can be used in the suppression of Class A and Class B fires. Laboratory tests were performed to determine whether or not the product has any effect on the analysis for ignitable liquids by GC, in particular for gasoline, medium petroleum distillates. and heavy petroleum distillates. Test burns were suppressed using either the micelle encapsulator or water and samples collected from these burns were analyzed. The results of analysis show that use of the micelle encapsulator at a fire scene may affect the chromatographic data obtained from samples collected by the investigator. However, the effect does not prevent the identification of common ignitable liquids in fire debris samples.