A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reproducibility analysis of a new objective method for measuring arteriovenous malformation nidus size at angiography. | LitMetric

Background And Purpose: Currently, no specific method exists to measure arteriovenous malformation (AVM) nidus size, a requirement in assessing the success of treatment. Additionally, the commonly used evaluation provides only a linear one-dimensional measurement of this three-dimensional entity. The purpose of this study was to devise an improved method for measuring AVM nidus size, an irregularly shaped radiologic entity, that provides objective and reproducible results.

Methods: The procedure involved digitizing angiograms obtained before and after treatment, making the gray scale uniform, printing images on standard bond paper, delineating the nidus area, measuring the nidus area with a polar planimeter, and finally, correcting for geometric magnification. Three observers made the measurements. The corrected nidus areas were tabulated, and the mean, standard deviation, interobserver variability, and confidence intervals (CIs) were calculated.

Results: On both anteroposterior and lateral views, the Kendall coefficient of concordance (a measure of interobserver variability) was equal to 0.97, signifying excellent agreement. Additionally, these values were within the 95% CIs; this result showed that they were unlikely the result of chance.

Conclusion: Precise measurements of an AVM nidus are required to properly analyze changes in the lesion after endovascular embolization (ie, to evaluate treatment success). Because of the irregular contours of an AVM nidus, measuring an area with planimetry, rather than with the usual linear dimensions, should yield more exact results.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7975293PMC

Publication Analysis

Top Keywords

avm nidus
16
nidus size
12
method measuring
8
arteriovenous malformation
8
nidus
8
nidus area
8
interobserver variability
8
reproducibility analysis
4
analysis objective
4
objective method
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!