Far-infrared to millimeter-wave bolometers designed to make astronomical observations are typically encased in integrating cavities at the termination of feedhorns or Winston cones. This photometer combination maximizes absorption of radiation, enables the absorber area to be minimized, and controls the directivity of absorption, thereby reducing susceptibility to stray light. In the next decade, arrays of hundreds of silicon nitride micromesh bolometers with planar architectures will be used in ground-based, suborbital, and orbital platforms for astronomy. The optimization of integrating cavity designs is required for achieving the highest possible sensitivity for these arrays. We report numerical simulations of the electromagnetic fields in integrating cavities with an infinite plane-parallel geometry formed by a solid reflecting backshort and the back surface of a feedhorn array block. Performance of this architecture for the bolometer array camera (Bolocam) for cosmology at a frequency of 214 GHz is investigated. We explore the sensitivity of absorption efficiency to absorber impedance and backshort location and the magnitude of leakage from cavities. The simulations are compared with experimental data from a room-temperature scale model and with the performance of Bolocam at a temperature of 300 mK. The main results of the simulations for Bolocam-type cavities are that (1) monochromatic absorptions as high as 95% are achievable with <1% cross talk between neighboring cavities, (2) the optimum absorber impedances are 400 ohms/sq, but with a broad maximum from approximately 150 to approximately 700 ohms/sq, and (3) maximum absorption is achieved with absorber diameters > or = 1.5 lambda. Good general agreement between the simulations and the experiments was found.

Download full-text PDF

Source
http://dx.doi.org/10.1364/ao.41.000136DOI Listing

Publication Analysis

Top Keywords

integrating cavities
12
optimization integrating
8
cavities
5
numerical optimization
4
integrating
4
cavities diffraction-limited
4
diffraction-limited millimeter-wave
4
millimeter-wave bolometer
4
bolometer arrays
4
arrays far-infrared
4

Similar Publications

Background: In the last years, artificial intelligence (AI) has contributed to improving healthcare including dentistry. The objective of this study was to develop a machine learning (ML) model for early childhood caries (ECC) prediction by identifying crucial health behaviours within mother-child pairs.

Methods: For the analysis, we utilized a representative sample of 724 mothers with children under six years in Bangladesh.

View Article and Find Full Text PDF

Minimally invasive dentistry (MID) has revolutionized pediatric dental care by emphasizing the preservation of healthy tooth structures, reducing treatment-related trauma, and improving patient compliance. This narrative review explores advancements in MID techniques, including silver diamine fluoride (SDF), resin infiltration, atraumatic restorative treatment (ART), bioactive materials, laser-assisted therapies, and three-dimensional (3D) printing technologies. These approaches prioritize early diagnosis, prevention, and conservative management, aligning with patient-centered and sustainable practices.

View Article and Find Full Text PDF

Mimicking the superstructures and properties of spherical biological encapsulants such as viral capsids and ferritin offers viable pathways to understand their chiral assemblies and functional roles in living systems. However, stereospecific assembly of artificial polyhedra with mechanical properties and guest-binding attributes akin to biological encapsulants remains a formidable challenge. Here we report the stereospecific assembly of dynamic supramolecular snub cubes from 12 helical macrocycles, which are held together by 144 weak C-H hydrogen bonds.

View Article and Find Full Text PDF

Laser diodes based on solution-processed semiconductor quantum dots (QDs) present an economical and color-tunable alternative to traditional epitaxial lasers. However, their efficiency is significantly limited by non-radiative Auger recombination, a process that increases lasing thresholds and diminishes device longevity through excessive heat generation. Recent advancements indicate that these limitations can be mitigated by employing spherical quantum wells, or quantum shells (QSs), in place of conventional QDs.

View Article and Find Full Text PDF

In conventional nondispersive infrared (NDIR) gas sensors, a wide-spectrum IR source or detector must be combined with a narrowband filter to eliminate the interference of nontarget gases. Therefore, the multiplexed NDIR gas sensor requires multiple pairs of narrowband filters, which is not conducive to miniaturization and integration. Although plasmonic metamaterials or multilayer thin-film structures are widely applied in spectral absorption filters, realizing high-performance, large-area, multiband, and compact filters is rather challenging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!