Object: With increasing use of endovascular procedures, the number of aneurysms treated surgically will decline. In this study the authors review complications related to the surgical treatment of aneurysms and address the issue of maintaining quality standards on a national level.

Methods: A prospective, nonselected amalgamation of every aneurysm case treated in five of six neurosurgical centers in Sweden during 1 calendar year was undertaken (422 patients; 7.4 persons/100,000 population/year). The treatment protocols at these institutions were very similar. Outcome was assessed using clinical end points. In this series, 84.1% of the patients underwent surgery, and intraoperative complications occurred in 30% of these procedures. Poor outcome from technical complications was seen in 7.9% of the surgically treated patients. Intraoperative aneurysm rupture accounted for 60% and branch sacrifice for 12% of all technical difficulties. Although these complications were significantly related to aneurysm base geometry and the competence of the surgeon, problems still occurred apparently at random and also in the best of hands (17%). The temporary mean occlusion time in the patients who suffered intraoperative aneurysm rupture was twice as long as the temporary arrest of blood flow performed to aid dissection.

Conclusions: The results obtained in this series closely reflect the overall management results of this disease and support the conclusion that surgical complications causing a poor outcome can be estimated on a large population-based scale. Intraoperative aneurysm rupture was the most common and most devastating technical complication that occurred. Support was found for a more liberal use of temporary clips early during dissection, regardless of the experience of the surgeon. Temporary regional interruption of arterial blood flow should be a routine method for aneurysm surgery on an everyday basis. A random occurrence of difficult intraoperative problems was clearly shown, and this factor of unpredictability, which is present in any preoperative assessment of risk, strengthens the case for recommending neuroprotection as a routine adjunct to virtually every aneurysm operation, regardless of the surgeon's experience.

Download full-text PDF

Source
http://dx.doi.org/10.3171/jns.2002.96.3.0515DOI Listing

Publication Analysis

Top Keywords

intraoperative aneurysm
12
aneurysm rupture
12
intraoperative complications
8
aneurysm
8
complications aneurysm
8
aneurysm surgery
8
poor outcome
8
blood flow
8
intraoperative
6
complications
5

Similar Publications

Aortitis, defined as inflammation of the aorta, can lead to aneurysms and dissections. Intra-operative sampling is essential for diagnosis, with many cases presenting asymptomatically as clinically isolated aortitis. Previous studies investigating aortitis in major aortic surgery have been limited by low intra-operative sampling.

View Article and Find Full Text PDF

Indocyanine green video angiography, integrated into the operative microscope, is frequently used in cerebrovascular surgery. This technology is often preferred, for cost or availability, to Doppler or intraoperative DSA (digital subtraction angiography). With the same assumption it was possible, in our preliminary experience, to partially vicariate the aforementioned devices using the SPY mode of the Stryker endoscope; it allowed the visualization of fluorescence in high definition.

View Article and Find Full Text PDF

Superior mesenteric artery (SMA) aneurysm and their surgical interventions are rare, leading to infrequent reports of postoperative complications. This report describes 2 cases of refractory diarrhea following vascular reconstruction for infectious SMA aneurysms. Both patients underwent aneurysm resection and SMA reconstruction but experienced persistent diarrhea despite treatment with anti-diarrheal medications.

View Article and Find Full Text PDF

Objective: This study offers a retrospective assessment of a single-center experience using cerebrospinal fluid catheters to reduce the risk of perioperative spinal cord injury in patients undergoing single-staged complex endovascular juxtarenal or thoracoabdominal aortic aneurysm repair.

Results: A total of 97 patients were included. On average, 70.

View Article and Find Full Text PDF

Acute thrombosis of ductus arteriosus aneurysm causing bilateral pulmonary artery occlusion in a neonate.

J Cardiothorac Surg

December 2024

Department of congenital heart surgery, Guangdong Cardiovascular Institute, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong Province, China.

A 9-day-old male neonate was found to have a systolic murmur during a routine follow-up for skin jaundice. Imaging revealed a large mass at the bifurcation of the main pulmonary artery, causing significant bilateral stenosis. The patient underwent emergency surgery due to critically compromised pulmonary blood flow.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!