Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Alkylphenol polyethoxylates (APEs) are a widely used group of nonionic surfactants in commercial production. Characterization of the composition of APE mixtures can be exploited for the determination of their most effective uses. In this study sample mixtures contain nonylphenol polyethoxylates and octylphenol polyethoxylates. The separation of individual alkylphenols by ethoxylate units is performed by supercritical fluid chromatography (SFC)-UV as well as normal-phase high-performance liquid chromatographic (HPLC)-UV employing packed columns. The stationary phase and column length are varied in the SFC setup to produce the most favorable separation conditions. Additionally, combinations of packed columns of different stationary phases are tested. The combination of a diol and a cyano column is found to produce optimal results. An advantage of using packed columns instead of capillary columns is the ability to inject large amounts of sample and thus collect eluted fractions. In this regard, fractions from SFC runs are collected and analyzed by flow injection analysis-electrospray ionization-mass spectroscopy in order to positively identify the composition of the fractions. In comparing the separation of APE mixtures by SFC and HPLC, it is found that SFC provides shorter retention times with similar resolution. In addition, less solvent waste is produced using SFC.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/chromsci/40.2.61 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!