This paper describes a comprehensive study of hepatitis C virus (HCV) and human immunodeficiency virus type 1 (HIV-1) genotype sensitivity of the transcription-mediated amplification (TMA)-based HIV-1/HCV assay, developed and manufactured by Gen-Probe Incorporated (San Diego, CA) for screening human plasma specimens in blood bank settings. The TMA HIV-1/HCV assay is a qualitative, in vitro nucleic acid testing system used for initial screening. HIV-1 and HCV discriminatory assays are used to distinguish between HIV-1 and HCV infection or co-infection. In this study, multiple unique specimens representing HCV genotypes 1-6 were tested at various dilutions. The results show that the TMA HIV-1/HCV assay and the TMA HCV discriminatory assay have similar HCV genotype sensitivity, as both assays detected all six genotypes at 100 copies/ml and nearly all replicates tested at 30 copies/ml. Similarly, numerous unique specimens representing HIV-1 group M subtypes (A-G), HIV-1 group N, and group O specimens were tested at various dilutions. The TMA HIV-1/HCV assay and the TMA HIV-1 discriminatory assay were found to have similar HIV-1 subtype sensitivity; all variants at 100 copies/ml and nearly all at 30 copies/ml were detected. These results indicate that the TMA assays meet the sensitivity requirements for blood screening in blood banks worldwide.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0166-0934(02)00012-5 | DOI Listing |
Open Forum Infect Dis
November 2023
Department of Infectious Diseases and Hospital Epidemiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Background: T-cell responses during chronic viral infections become exhausted, which is reflected by upregulation of inhibitory receptors (iRs) and increased interleukin 10 (IL-10). We assessed 2 iRs-PD-1 (programmed cell death protein 1) and Tim-3 (T-cell immunoglobulin and mucin domain-containing protein 3)-and IL-10 mRNAs in peripheral blood mononuclear cells (PBMCs) and their soluble analogs (sPD-1, sTim-3, and IL-10) in plasma in chronic HIV-1/hepatitis C virus (HCV) coinfection and explored the effect of HCV treatment on these markers. We also aimed to establish whether iR expression may be determined by the HCV CD8 T-cell immunodominant epitope sequence.
View Article and Find Full Text PDFTransfusion
November 2023
Grifols Diagnostic Solutions Inc., San Diego, California, USA.
Background: Commercial multiplex nucleic acid tests (NATs) for HIV-1/HIV-2/HCV/HBV are widely used in developed countries to screen blood donations. HEV NAT screening has been implemented in some blood banks but is tested with a different assay.
Study Design And Methods: This study describes the clinical sensitivity and specificity of the Procleix® UltrioPlex E (UPxE) assay on the automated Procleix Panther® system for the simultaneous detection of HIV-1/HIV-2/HCV/HBV/HEV.
Anal Chim Acta
July 2023
Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Pathumwan, Bangkok, 10330, Thailand. Electronic address:
Electrochemical DNA sensors can be operated in either static or flow-based detection schemes. In static schemes, manual washing steps are still necessary, resulting in a tedious and time-consuming process. In contrast, in flow-based electrochemical sensors, the current response is collected when the solution flows through the electrode continuously.
View Article and Find Full Text PDFDiagn Microbiol Infect Dis
July 2023
Department of Pathology, Division of Medical Microbiology, The Johns Hopkins University School of Medicine, Baltimore, MD, USA. Electronic address:
The clinical performance of the Aptima® HIV-1 Quant Dx, Aptima HCV Quant Dx, and Aptima HBV Quant Dx were evaluated and compared to the Roche cobas HIV-1, HCV, and HBV assays performed on the Roche cobas 6800 system. The Aptima Quant assays exhibited an overall percent agreement of 99.4% for HBV, 98.
View Article and Find Full Text PDFCell Rep
February 2023
Vanderbilt Vaccine Center, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Department of Pathology, Microbiology and Immunology, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Vanderbilt Institute for Infection, Immunology, and Inflammation, Vanderbilt University Medical Center, Nashville, TN 37232, USA; Department of Computer Science, Vanderbilt University, Nashville, TN 37232, USA; Center for Structural Biology, Vanderbilt University, Nashville, TN 37232, USA; Program in Computational Microbiology and Immunology, Vanderbilt University Medical Center, Nashville, TN 37232, USA. Electronic address:
Despite prolific efforts to characterize the antibody response to human immunodeficiency virus type 1 (HIV-1) and hepatitis C virus (HCV) mono-infections, the response to chronic co-infection with these two ever-evolving viruses is poorly understood. Here, we investigate the antibody repertoire of a chronically HIV-1/HCV co-infected individual using linking B cell receptor to antigen specificity through sequencing (LIBRA-seq). We identify five HIV-1/HCV cross-reactive antibodies demonstrating binding and functional cross-reactivity between HIV-1 and HCV envelope glycoproteins.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!