A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental evaluation of a new transcatheter vascular embolization device in the swine model. | LitMetric

Experimental evaluation of a new transcatheter vascular embolization device in the swine model.

J Vasc Interv Radiol

Division of Pediatric Cardiology, The Johns Hopkins Medical Institutions, Baltimore, MD, USA.

Published: March 2002

Purpose: To evaluate a new transcatheter device suitable for arterial embolization in an animal model.

Materials And Methods: A new prototype self-expanding braided embolic device (Embolizor), consisting of nitinol wire strands fixed at either end with platinum-iridium bands and covered with a film of polyethylene, was deployed through 5-F diagnostic catheters into renal artery branches in five swine. Standard stainless-steel spring coils were deployed in other renal branches and served as controls. The animals underwent follow-up selective renal arteriography to determine presence or absence of vessel recanalization or device migration 15-23 days after device deployment. Histopathologic evaluation of target vessels and peripheral renal parenchyma was also performed.

Results: Ten Embolizors and 10 stainless-steel coils were deployed in arteries ranging in size from 1.8 to 3.0 mm in diameter. The Embolizor was easily and precisely deployed. Angiographic evidence of vascular occlusion in the Embolizor group was noted within 30 seconds in eight device deployments and within 5 minutes in two. No early or delayed device migration was noted on follow-up arteriography. In the control group, seven of 10 previously occluded arteries were recanalized. No recanalization was noted in the Embolizor group. Light microscopy revealed evidence of infarction in all specimens examined. Whereas three specimens in the Embolizor group contained occasional giant cells, there were numerous multinucleated giant cells present within the interstices of all control spring coils.

Conclusion: The Embolizor was easily, precisely, and successfully deployed through standard selective diagnostic angiographic catheters. Short-term follow-up demonstrated no recanalization or migration of the device. The Embolizor was shown on histopathologic analysis to have no significant foreign body reaction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s1051-0443(07)61724-2DOI Listing

Publication Analysis

Top Keywords

embolizor group
12
device
8
device embolizor
8
coils deployed
8
device migration
8
embolizor easily
8
easily precisely
8
precisely deployed
8
giant cells
8
embolizor
7

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!