Current noninvasive techniques for the routine and frequent quantification of peripheral lymphedema in patients are total limb volume measurement (by water immersion or by circumferential measurements) and bioelectrical impedance analysis (BIA). However both of these techniques require standardizing the measurement using a contralateral measurement from the unaffected limb. Hence these techniques are essentially restricted to unilateral lymphedema. This paper describes the results from a preliminary study to investigate an alternative approach to the analysis of the data from multiple frequency BIA to produce an index of lymphedema without the need for normalization to another body segment. Twenty patients receiving surgical treatment for breast cancer were monitored prior to surgery and again after diagnosis with unilateral lymphedema. The data recorded were total limb volume, by circumferential measurements; and BIA measurements of both limbs. From these measurements total limb volumes and extracellular fluid volumes were calculated and expressed as ratios of the affected limb to that of the unaffected limb. An index of the ratio of the extracellular fluid volume to the intracellular fluid volume was determined. This ECW/ICW index was calculated for both the affected and unaffected limbs at both measurement times. Results confirmed that the established techniques of total limb volume and extracellular fluid volume normalized to the unaffected contralateral limb were accurate in the detection of lymphedema (p < 10(-6)). Comparison of the ECW/ICW index from the affected limb after diagnosis with that from the pre-surgery measurement revealed a significant (p < 10(-6)) and considerable (75%) increase. The results of this pilot study suggest that by using multiple frequency bioelectrical impedance analysis, an index of the ECW/ICW ratio can be obtained and this index appears to have an equal, or better, sensitivity than the other techniques in detecting lymphedema. More importantly, this index does not require normalization to another body segment and can be used to detect all types of peripheral edema including both unilateral and bilateral lymphedema.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/000331970205300106 | DOI Listing |
Mater Today Bio
February 2025
Northern Jiangsu People's Hospital, Yangzhou, Jiangsu, China.
Spinal cord injury (SCI) is a neurological condition that causes significant loss of sensory, motor, and autonomic functions below the level of injury. Current clinical treatment strategies often fail to meet expectations. Hyaluronidase is typically associated with tumor progression and bacterial infections.
View Article and Find Full Text PDFCureus
December 2024
Radiology, SRM Medical College Hospital and Research Center, Chennai, IND.
Intraoperative neurophysiological monitoring (IONM) has achieved popularity because it facilitates monitoring of the functional integrity of neural structures under general anesthesia. It aids in the early detection of injury and minimizes postoperative neurologic deficit or neurologic morbidity from surgical manipulations of various neurologic structures. The patient mentioned in this case report presented with lower limb radiculopathy and was diagnosed with diastematomyelia Type II, and she was planned for surgical intervention under general anesthesia.
View Article and Find Full Text PDFCureus
December 2024
Vascular Surgery, Centro Médico Nacional 20 de Noviembre, Mexico City, MEX.
This case report evaluates current diagnostic and treatment approaches for intrapelvic acetabular migration, focusing on the rare but serious complication of acute limb ischemia following hip arthroplasty. A 67-year-old female with a history of total hip arthroplasty 10 years ago presented with acute limb ischemia after experiencing a traumatic event 72 hours prior, which had caused displacement of her hip prosthesis. Notably, she had a history of a traumatic event two years earlier for which she had been advised to undergo surgical correction, which she had refused.
View Article and Find Full Text PDFCureus
December 2024
Trauma and Orthopaedics, Northampton General Hospital, Northampton, GBR.
Although mixing and matching components is a common, safe, and well-documented practice in hip revision surgery, our extensive search indicates that it has not been previously reported for shoulder arthroplasty. This case report presents the use of mixed implants in shoulder revision surgery to reduce morbidity and address flaws in the initial implant design. We describe a case of a patient with multiple epiphyseal dysplasia who was treated for osteoarthritis in his left shoulder with an anatomic shoulder replacement in 2014.
View Article and Find Full Text PDFFront Neurol
December 2024
School of Physical Education and Sports Science, South China Normal University, Guangzhou, Guangdong, China.
Background: This study aims to evaluate the optimal rehabilitation regimen for lower limb dysfunction in stroke patients by analyzing the effects of proprioceptive training (PT) in combination with different rehabilitation interventions.
Methods: Randomized controlled trials (RCTs) published up to April 23, 2024, were searched from PubMed, Embase, Cochrane Library, Web of Science, CNKI, Wanfang, VIP, and SinoMed. The quality of the included studies was assessed using the Cochrane Risk of Bias tool (ROB 2.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!