Background: This follow-up study updates the results in a consecutive series of nineteen cemented total hip replacements with a swan-neck femoral component in patients with congenital dislocation or severe hip dysplasia. The series was previously reported on in 1993.

Methods: The patients were petite, with an average height of 152 cm and an average weight of 50 kg, and the femoral canals could not accommodate an off-the-shelf femoral component. Sixteen of the nineteen hips were available for follow-up at an average of 13.3 years (range, eleven to twenty years). Fourteen hips had up-to-date clinical and radiographic examinations.

Results: At the time of the latest follow-up, thirteen hips were rated as excellent; two, as good; and one, as a failure because of loosening of both components requiring revision eleven years after the index operation. Another hip required acetabular revision because of loosening fifteen years after the index operation. The rates of femoral and acetabular component revision were 6% and 12.5%, respectively. Radiographic analysis demonstrated that no femoral component was loose. One cup was definitely loose at 19.5 years, and three cups were possibly loose at an average of fourteen years. The radiographic rate of acetabular loosening was 33%. The total rate of cup failure (radiographic loosening and revision) was 43%.

Conclusions: The excellent clinical and radiographic results associated with the swan-neck femoral component, and the 94% rate of survival, at an average of 13.3 years (range, eleven to twenty years) indicate that the biomechanical objectives of this custom-designed prosthesis for patients with congenital dislocation or severe hip dysplasia were met. On the basis of this favorable long-term experience, we still use this prosthesis when the anatomic abnormality cannot be adequately addressed by use of a commercially available prosthetic component.

Download full-text PDF

Source
http://dx.doi.org/10.2106/00004623-200202000-00006DOI Listing

Publication Analysis

Top Keywords

femoral component
20
swan-neck femoral
12
congenital dislocation
12
dislocation severe
12
total hip
8
patients congenital
8
severe hip
8
hip dysplasia
8
average 133
8
years
8

Similar Publications

Introduction: The outcomes of total hip arthroplasty (THA) are highly dependent upon the restoration of native hip biomechanics and optimal component positioning. Robotic technologies for THA have rapidly improved the accuracy of component positioning and maintaining the planned center of rotation. While robotic-assisted THA (RA-THA) has primarily been employed in surgically intricate cases, its potential benefits in scenarios of diminished surgical complexity remain less explored.

View Article and Find Full Text PDF

Objective: Animal models of nerve injury are important for studying nerve injury and repair, particularly for interventions that cannot be studied in humans. However, the vast majority of gait analysis in animals has been limited to univariate analysis even though gait data is highly multi-dimensional. As a result, little is known about how various spatiotemporal components of the gait relate to each other in the context of peripheral nerve injury and trauma.

View Article and Find Full Text PDF

A Unique Cause of Chronic Right Hip Pain and Unilateral Leg Swelling 10 Years Following Total Hip Arthroplasty.

Am J Phys Med Rehabil

November 2024

Department of Physical Medicine & Rehabilitation, University of Minnesota, Minneapolis, Minnesota.

Patient is a 64-year-old female with a history of right total hip arthroplasty (THA) who presented with progressive painful right lower extremity edema and chronic groin pain for 2 years. A CT scan from October 2021 revealed an expanding, large iliopsoas bursal fluid collection that caused compression of the right common femoral artery and vein in June 2023. Further workup excluded deep venous thrombosis or infectious causes.

View Article and Find Full Text PDF

Introduction: A primary objective when performing a total hip arthroplasty (THA) is to restore hip biomechanics in accordance with a chosen surgical plan. The aim of this study was to assess the accuracy of a 3D-printed patient-specific guide for delivering a planned femoral osteotomy for both a posterior and an anterior approach.

Methodology: 40 patients (20 anterior and 20 posterior) scheduled for THA received a preoperative work-up allowing for patient-specific implant sizing and positioning.

View Article and Find Full Text PDF

Background: Total Hip Arthroplasty (THA) is a transformative surgical intervention for hip joint disorders, necessitating meticulous preoperative planning for optimal outcomes. With the emergence of Artificial Intelligence (AI), preoperative planning paradigms have evolved, leveraging AI algorithms for enhanced decision support and imaging analysis. This systematic review aims to comprehensively evaluate the role of AI in THA preoperative planning, synthesizing evidence from studies exploring various AI techniques and their applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!