A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Analysis of the saliva from patients with oral cancer by matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. | LitMetric

Using matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS), this study analyzed the saliva obtained from patients with oral cancer and compared these mass spectra with those obtained from healthy controls. Saliva without pre-treatment was mixed directly with a sinapinic acid matrix. Alpha-amylase (57 kDa) dominated the high mass range in the MALDI mass spectra of the saliva from healthy subjects, but the peak was suppressed for patients with oral cancer and was replaced by a peak at m/z 66 k in the spectra of patients' samples (15 out of 20). Sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) with in-gel tryptic digestion combined with matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) was employed to characterize this 66-kDa protein, which was thus shown to be albumin. However, based on SDS-PAGE results, concentrations of both alpha-amylase and albumin in patients' saliva were significantly higher than those in healthy subjects. This discrepancy was shown to be due to MALDI suppression effects due to the albumin. MALDI-MS thus has potential as a possible rapid diagnostic screening tool for oral cancer.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcm.588DOI Listing

Publication Analysis

Top Keywords

oral cancer
16
patients oral
12
matrix-assisted laser
12
laser desorption/ionization
12
saliva patients
8
desorption/ionization time-of-flight
8
mass spectrometry
8
mass spectra
8
healthy subjects
8
mass
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!