Objective: To describe our experience with endoluminal stent graft repair of aortobronchial fistulas.

Methods: We reviewed the records of patients treated with endoluminal stent grafting of aortobronchial fistulas at a private teaching hospital. All patients underwent the following diagnostic studies: computed tomography, angiography, bronchoscopy, and transesophageal echocardiography. With standard endovascular techniques, two different devices were implanted.

Results: Between March 1997 and October 2000, we treated four patients with postsurgical fistulas. The patients were diagnosed with hemoptysis between 3 and 23 years after aortic replacement grafting for thoracic aneurysms. Diagnostic studies varied in their ability to find the fistula. Transesophageal echocardiography most reliably demonstrated the fistula in the patients. All were successfully treated by exclusion with endoluminal stent grafting. The patients had no complications and no further episodes of hemoptysis.

Conclusion: Endoluminal stent grafting of aortobronchial fistulas is feasible and may become the preferred method of management in patients at high risk.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mva.2002.118583DOI Listing

Publication Analysis

Top Keywords

endoluminal stent
20
aortobronchial fistulas
12
stent grafting
12
stent graft
8
graft repair
8
repair aortobronchial
8
patients treated
8
grafting aortobronchial
8
diagnostic studies
8
transesophageal echocardiography
8

Similar Publications

Evaluation of in-stent restenosis after carotid artery stenting with superb microvascular imaging: initial findings.

Acta Radiol

January 2025

Department of Radiology, Interventional Radiology, Sağlık Bilimleri Üniversitesi Ankara Dışkapı Yıldırım Beyazıt Eğitim ve Araştırma Hastanesi, Ankara, Türkiye.

Background: Carotid artery stenting (CAS) is an interventional management in preventing ischemic stroke caused by carotid artery stenosis. After the treatment with CAS, in-stent restenosis caused by neointimal hyperplasia may develop.

Purpose: This study aims to obtain a better determination of neointimal hyperplasia using superb microvascular imaging (SMI), which provides a high-quality visualization of the endoluminal lesions, and to compare these results with B-mode and Doppler ultrasound (US).

View Article and Find Full Text PDF

Transcatheter Pulmonary Flow Restrictors as a Palliative Bridge to Heart Transplant.

Pediatr Transplant

February 2025

Division of Pediatric Cardiology, Department of Pediatrics and Adolescent Medicine, Mayo Clinic, Rochester, Minnesota, USA.

Background: In recent years, transcatheter implantation devices to restrict pulmonary arterial flow have emerged as a potential alternative to surgical pulmonary artery banding.

Case Presentation: A term male was diagnosed with critical aortic stenosis (AS) and severely reduced left ventricle (LV) systolic function. He underwent aortic balloon valvuloplasty on day 2 of life, resulting in some antegrade flow, but LV ejection fraction only improved to 15%.

View Article and Find Full Text PDF

Rationale: Aortoesophageal fistula (AEF) is an exceedingly rare yet critically life-threatening condition, with mortality rates nearing 100% if not addressed promptly. AEF often develops in the context of thoracic aortic aneurysms, esophageal malignancies, or as a complication of foreign body ingestion and prior thoracic aortic surgeries. This study reports an exceptionally severe and clinically rare case of AEF associated with a pseudaneurysm induced by esophageal stenting.

View Article and Find Full Text PDF

3D printing in palliative medicine: systematic review.

BMJ Support Palliat Care

December 2024

Health Research Institute, School of Design, and Confirm Smart Manufacturing Centre, University of Limerick, Limerick, Ireland

Background: Three-dimensional printing (3DP) enables the production of highly customised, cost-efficient devices in a relatively short time, which can be particularly valuable to clinicians treating patients with palliative care intent who are in need of timely and effective solutions in the management of their patients' specific needs, including the relief of distressing symptoms.

Method: Four online databases were searched for articles published by December 2020 that described studies using 3DP in palliative care. The fields of application, and the relevant clinical and technological data were extracted and analysed.

View Article and Find Full Text PDF

Introduction: The Flow Re-direction Endoluminal Device (FRED) is a novel flow diverter with a unique double stent design, with an inner stent composed of 48 nitinol wires, and an outer stent with 16 nitinol wires. It is designed for endovascular cerebral aneurysm treatment, although, limited data exist regarding in-stent stenosis (ISS) rates associated with FRED devices.

Methods: A registry encompassing two North American comprehensive stroke centers was the base of this study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!