To examine the optimal pH range for growth on media, growth of Legionella spp. on its selective media, BCYE alpha, WYO alpha and MWY agar media, in a pH range of 6.0-8.0 (at 0.5 intervals) was compared. The growth of two strains of L. pneumophila and one strain of L. micdadei on a WYO alpha agar supplemented with some selecting antimicrobial agents was markedly inhibited at all pH range except 6.0 and 7.0, suggesting a narrow optimal pH range for growth of these species compared to the BCYE alpha without selecting antimicrobioal agents. Vancomycin (VCM) added to the selective agar suppressed the growth of some Legionella spp. depending on the concentration. However, the extent of suppression was different among species and/or strains of Legionella spp. The selectivity for species other than Legionella spp. was also affected similarly by VCM concentration added to their media, suggesting that it is important to use proper amounts of the selecting antimicrobial agent depending on the species and/or strains of Legionella spp. or the other species in water samples. Amphothericin B (AMPH-B) added to a selective medium, MWY agar, in the concentration of 80 micrograms/ml hardly affected the growth of Legionella spp. examined, but effectively inhibited the growth of fungal strains identified as Aspergillus sp., Trichoderma sp., Scolecobasidium sp. and Mucor sp. which were isolated from cooling-tower water samples together with Legionella spp. Furthermore, the growth of a combination culture of one each of the 4 strains of isolated fungi and one each of the 3 strains of Legionella spp. was examined at various concentration of AMPH-B. Addition of AMPH-B to the selective medium at the concentration of 80 micrograms/ml suppressed the growth of spreading fungi, permitting the growth of Legionella spp. to allow efficient detection of the species.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.11150/kansenshogakuzasshi1970.76.41 | DOI Listing |
J Epidemiol Glob Health
January 2025
Key Laboratory of Respiratory Disease of Zhejiang Province, Department of Respiratory and Critical Care Medicine, The Second Affiliated Hospital of Zhejiang University School of Medicine, Hangzhou, Zhejiang, China.
Background: Legionella infections are a major global health issue, yet there's limited research on their impact and trends. We aimed to systematically analyzed the long-term trends in Legionella spp. infection-associated diseases (LSIADs) burden from 1990 to 2021.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Biological, Geological, and Environmental Sciences, University of Bologna, Bologna, Italy.
The identification and typing of bacteria are very expensive and time-consuming due to their growth times, and the expertise needed. MALDI-TOF MS represents a fast technique, reproducible with molecular approaches. This technique is still poorly applied in Legionella surveillance with estimation occurring only at the genus level.
View Article and Find Full Text PDFMicroorganisms
December 2024
School of Life Sciences, University of Essex, Wivenhoe Park, Colchester, CO4 3SQ, UK.
Multiple human and plant pathogens are dispersed and transmitted as bioaerosols (e.g., , SARS-CoV-2, , , spp.
View Article and Find Full Text PDFJ Appl Microbiol
January 2025
University of Eastern Finland, Department of Environmental and Biological Sciences, P.O. Box 1627, FI-70211 Kuopio, Finland.
Aims: We investigated the combined effects of pipe materials and disinfection chemicals on bacterial community and its active RNA fraction in water and biofilms in a pilot-scale premise plumbing system.
Methods And Results: The changes in bacterial communities were studied within four pipelines using copper and cross-linked polyethylene (PEX) pipe with chlorine or chloramine disinfection. The total and active bacterial communities and the presence of opportunistic pathogens (Legionella spp.
J Water Health
December 2024
US Environmental Protection Agency, Office of Research and Development, Cincinnati, OH 45268, USA.
Hot water systems are the most frequent environment associated with the prevalence and growth of opportunistic premise plumbing pathogens (OPPPs). Previous studies identified water heaters as a source of waterborne diseases and concluded that design variables may contribute to their prevalence. A multifaceted approach was used to investigate the vertical stratification of the microbiome and selected OPPPs in an electric water heater tank connected to a home plumbing system simulator.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!