We studied lung mechanics and regional lung function in five young men during restrictive chest strapping. The effects on lung mechanics were similar to those noted by others in that lung elastic recoil increased as did maximum expiratory flow at low lung volumes. Chest strapping reduced the maximum expiratory flow observed at a given elastic recoil pressure. Breathing helium increased maximum expiratory flow less when subjects were strapped than when they were not. These findings indicated that strapping decreased the caliber of airways upstream from the equal pressure point. Regional lung volumes from apex to base were measured with xenon 133 while subjects were seated. The distribution of regional volumes was measured at RV, and at volumes equal to strapped FRC and strapped TLC; no change due to chest strapping was observed. Similarly, the regional distribution of 133Xe boluses inhaled at RV and strapped TLC was unaffected by chest strapping. Closing capacity decreased with chest strapping. We concluded that airway closure decreased during chest strapping and that airway closure was not the cause of the observed increase in elastic recoil of the lung. The combination of decreased slope of the static pressure-volume curve and unchanged regional volumes suggested that strapping increased the apex-to-base pleural pressure gradient.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1152/jappl.1975.39.5.707 | DOI Listing |
Cureus
December 2024
College of Health Care Sciences, Nova Southeastern University, Fort Lauderdale, USA.
The case report explores the effects of testosterone replacement therapy (TRT) on body composition, lean muscle mass, and fat mass, based on the dosage of TRT and exercise intensity in a 40-year-old male. The purpose of this case study was to evaluate the dose-response relationship of TRT and exercise on muscle hypertrophy and fat loss over an eight-month period, using a validated wrist-worn wearable fitness tracker to measure daily physical activity and heart rate (HR)-based exercise intensity. The patient, a trained male with 25 years of consistent exercise experience, reported notable declines in strength and increases in body fat despite maintaining a regular workout routine.
View Article and Find Full Text PDFJ Funct Morphol Kinesiol
December 2024
Health & Human Physiological Sciences, Skidmore College, Saratoga Springs, NY 12866, USA.
Background: The Apple Watch provides promising health data that could aid in increasing exercise adherence; regular exercise can help individuals manage and prevent diseases such as obesity and cardiovascular disease. However, the impact of skin pigmentation on the accuracy of the Apple Watch Series 9 for measures of energy expenditure (EE) and heart rate (HR) is unknown.
Purpose: The purpose of this study was to determine the accuracy of the Apple Watch Series 9 on various skin pigmentations for measures of EE and HR.
Aerosp Med Hum Perform
December 2024
Introduction: Military pilots are subjected to unique pulmonary demands, particularly in high performance jets. The hypobaric environment necessitates use of on-board oxygen, breathing masks, and regulators to increase oxygen pressure, affecting ventilation and breathing responses. Safety features like pilot flight equipment and strapping into an ejection seat further impact pilot pulmonary function.
View Article and Find Full Text PDFJMIR Biomed Eng
December 2024
Department of Physical Therapy, Universidade Federal de Ciências da Saúde de Porto Alegre - UFCSPA, Porto Alegre, Brazil.
Background: Wearable sensors are rapidly evolving, particularly in health care, due to their ability to facilitate continuous or on-demand physiological monitoring.
Objective: This study aimed to design and validate a wearable sensor prototype incorporating photoplethysmography (PPG) and long-range wide area network technology for heart rate (HR) measurement during a functional test.
Methods: We conducted a transversal exploratory study involving 20 healthy participants aged between 20 and 30 years without contraindications for physical exercise.
Front Pharmacol
November 2024
Department of Pharmacy, the Hospital of Shandong University, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, China.
Dichloromethane is widely used as an organic solvent in aerospace, electronics, and medicine. Cases of poisoning caused by this substance are rare. Recently, we successfully treated a patient with an acute dichloromethane poisoning.