Molecular mechanics (MM4) force field development for phosphine and its alkyl derivatives.

Chirality

The Computational Center for Molecular Structure and Design, Department of Chemistry, University of Georgia, Athens, Georgia, USA.

Published: April 2002

Based on the experimental structures and vibrational spectra of eight alkylphosphines, as well as ten ab initio calculated (MP2/6-31+g*) structures and five potential energy profiles, the MM4 force field has been extended to include this important functional group. The results are comparable to experimental values for phosphorus-containing compounds. The addition of various cross-terms significantly improved the MM4 calculated structures relative to its predecessor, MM3. The overall root mean square error in moments of inertia have been reduced from 1.65% in MM3 to 0.26% in MM4. MM4 was also successful in reducing the previously impressive root mean square error in vibrational frequencies from 35 cm(-1) to 31 cm(-1) for the eight compounds studied.

Download full-text PDF

Source
http://dx.doi.org/10.1002/chir.10066DOI Listing

Publication Analysis

Top Keywords

mm4 force
8
force field
8
root square
8
square error
8
mm4
5
molecular mechanics
4
mechanics mm4
4
field development
4
development phosphine
4
phosphine alkyl
4

Similar Publications

We selected 145 reference organic molecules that include model fragments used in computer-aided drug design. We calculated 158 conformational energies and barriers using force fields, with wide applicability in commercial and free softwares and extensive application on the calculation of conformational energies of organic molecules, e.g.

View Article and Find Full Text PDF

Bonded (or valence) interactions, which directly determine the local structures of the molecules, are fundamental parts of molecular mechanics force fields (FFs). Most popular classical FFs adopt the simple harmonic models for bond stretching and angle bending and ignore cross-coupling effects among the valence terms. This may lead to less accurate vibrational properties and configurations in molecular dynamics (MD) simulations.

View Article and Find Full Text PDF

[Utilization of UiO-66-NH@cellulose hybrid aerogel for solid-phase extraction of sildenafil in health products].

Se Pu

June 2022

School of Chemistry and Chemical and Engineering, Guangxi University for Nationalities, Key Laboratory of Chemistry and Engineering of Forest Products, State Ethnic Affairs Commission, Guangxi Key Laboratory of Chemistry and Engineering of Forest Products, Guangxi Collaborative Innovation Center for Chemistry and Engineering of Forest Products, Key Laboratory of Guangxi Colleges and Universities for Food Safety and Pharmaceutical Analytical Chemistry, Nanning 530008, China.

Sildenafil is a prescription drug used to treat pulmonary hypertension and erectile dysfunction. However, the illegal addition of sildenafil to health supplements may be hazardous to human health. Therefore, it is imperative to develop a method for the detection of sildenafil in health products.

View Article and Find Full Text PDF

Deviations in positioning variable pitch screws- scaphoid waist fractures.

Orthop Traumatol Surg Res

April 2020

Department of Trauma-, Hand- and Reconstructive Surgery, University Jena, Germany; Department of Trauma, BG Bergmanstrost, Halle, Germany.

Introduction: Operative therapy using a headless cannulated variable pitch compression screw is the gold standard for the treatment of instable scaphoid fractures.

Hypothesis: Deviation from the central placement is associated with a loss of stability and stiffness.

Material And Methods: An artificial bone model was manufactured and different screw positions (central, 10° and 20° to the long axis) were assessed.

View Article and Find Full Text PDF

Introduction: The aim of this study was to evaluate the effect of different heights of attachment and mucosa thicknesses on the stress distribution of two implant-retained mandibular overdenture designs under loading using the photoelastic stress analysis method.

Materials And Methods: Six photoelastic models of an edentulous mandibula were fabricated with two solitary implants that were placed in the canine regions. The attachment systems studied were ball and locator stud attachments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!