A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The deterioration of rotary nickel-titanium files under controlled conditions. | LitMetric

The deterioration of rotary nickel-titanium files under controlled conditions.

J Endod

Department of Stomatology, Houston Biomaterials Research Center, University of Texas-Houton Health Science Center, 77030-3402, USA.

Published: February 2002

It has been shown that rotary nickel-titanium files cannot be used indefinitely. Researchers and clinicians have not been able to agree on how many times a file can be used before being discarded, except if a file has fractured or become visibly distorted. This study used ISO size 20 files of 0.04 taper in the curved canals of extracted mandibular molars. The canals had been previously instrumented to an ISO size 15 with stainless steel hand files. The irrigant used during rotary and hand instrumentation was Glyde. The rotary files were closely examined with scanning electron microscopy before use to detect any defects. They were then reexamined after each of five uses to document deterioration. An electric handpiece was configured to rotate at 150 rpm and secured to the testing device, which also held the extracted tooth. The testing device controlled the load at 8 N, the depth of penetration for each canal and the rate of penetration (12 mm/min). Used instruments demonstrated surface fatigue wear and cracking. Torsional moment at failure was determined on a torsiometer for used and new instruments. Data (n = 10) were analyzed by analysis of variance. The torsional moment for used and new instruments was not affected by use (p = 0.25).

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004770-200202000-00014DOI Listing

Publication Analysis

Top Keywords

rotary nickel-titanium
8
nickel-titanium files
8
iso size
8
testing device
8
torsional moment
8
files
5
deterioration rotary
4
files controlled
4
controlled conditions
4
conditions rotary
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!