A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Continuous monitoring of arterial blood gases and pH during laparoscopic cholecystectomy using a Paratrend sensor. | LitMetric

Background: The safety of laparoscopic procedures has been studied broadly. The effects on cardiopulmonary function and reliable methods of monitoring concentrate more interest.

Methods: A prospective study in 22 consecutive patients with ASA I and II was designed. The continuous assessment of alterations of arterial blood gases, pH, arterial pressure and heart rate during laparoscopic cholecystectomy by carbon dioxide pneumoperitoneum American technique was achieved using an intra-vascular multi-parameter sensor Paratrend.

Results: Statistically significant increase of both PaCO2 and PE.CO2 in parallel and a corresponding decrease of pH were found in correlation with the duration of the pneumoperitoneum. The values of PaO2, Sat O2, base excess, H-CO3, mean arterial pressure and heart rate showed no statistically significant alterations at any time throughout the procedure. No differences were noted between younger patients and in the elderly or between patients with ASA I and II.

Conclusions: Intra-arterial blood-gas sensor ensures continuous on-line monitoring, but no abnormal and threatening changes occur during laparoscopic cholecystectomy in otherwise healthy people.

Download full-text PDF

Source

Publication Analysis

Top Keywords

laparoscopic cholecystectomy
12
arterial blood
8
blood gases
8
patients asa
8
arterial pressure
8
pressure heart
8
heart rate
8
continuous monitoring
4
arterial
4
monitoring arterial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!