Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To investigate the effects of caudal analgesia on the minimal alveolar concentration of enflurane for laryngeal mask airway (LMA) smooth extubation (MACex).
Methods: We studied 50 nonpremedicated children, aged three to ten years, ASA physical status I, undergoing surgery for hypospadias repair. After a sevoflurane inhalation induction, children were randomized to receive LMA insertion with or without ropivacaine caudal analgesia. At the end of surgery, a predetermined end-tidal enflurane concentration was achieved, and the LMA was removed by an anesthesiologist blinded to group allocation. Each concentration at which LMA extubation was attempted was predetermined by the up-and-down method (with 0.1% as the step size). When LMA removal was accomplished without coughing, clenching teeth or gross purposeful muscular movements during or within one minute after removal, it was considered successful.
Results: MACex of enflurane for LMA removal in the group without caudal anesthesia was 1.04% (95% confidence interval, 1.00-1.10) and the LMA MACex of enflurane in the group with caudal anesthesia was 0.74% (95% confidence interval, 0.63-0.81). Caudal analgesia significantly reduced enflurane requirements by 29% (95% confidence interval, 22-36%).
Conclusion: In conclusion, caudal analgesia significantly reduced the LMA MACex of enflurane by approximately 29%. Possible mechanisms may be related to the analgesic effect of caudal blockade or to the sedative properties of neuraxial anesthesia.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/BF03020495 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!