Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To determine differences in the signal intensity (SI) time courses at oxygen-enhanced magnetic resonance (MR) lung imaging in healthy volunteers and patients with pulmonary diseases and to correlate these differences with pulmonary diffusing capacity.
Materials And Methods: Seventeen patients with pulmonary diseases and 11 healthy volunteers underwent oxygen-enhanced MR imaging while they breathed room air and 100% oxygen. A turbo spin-echo sequence with global or section-selective inversion pulses was used. For postprocessing, SI slope maps during the breathing of 100% oxygen were calculated. Mean SI slope and SI change values were compared with the diffusing capacity of the lung for carbon monoxide (DLCO).
Results: The SI slopes were significantly different for patients and volunteers (P < or = .05, Mann-Whitney U test). Linear correlations were detected between the DLCO and SI slopes for the section-selective inversion pulse (r(2) = 0.81) and the global inversion pulse (r(2) = 0.74). A lower correlation was associated with the SI change for the section-selective pulse (r(2) = 0.04; global pulse, r(2) = 0.81). Regional differences were seen in the SI slope and SI change maps. These differences correlated with findings on radiographs and computed tomographic scans.
Conclusion: The SI slope during the breathing of 100% oxygen allows spatially resolved assessment of the pulmonary diffusion capacity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1148/radiol.2222000869 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!