We investigated whether serum cardiac troponin T levels are altered in septic patients undergoing hemodialysis and whether polyinyxin B-immobilized fiber (PMX-F) treatment affects these levels. Fourteen heinodialysis patients with sepsis, 14 hemodialysis patients without sepsis, and 12 age matched healthy controls were included in this study. Cardiac troponin T levels in hemodialysis patients with sepsis (0.56+/-0.28 microg/L) were higher than levels in hemodialysis patients without sepsis (0.16+/-0.06 microg/L, p < 0.01) and healthy control subjects (0.03+/-0.01 microg/L, p < 0.001). The 14 hemodialysis patients with sepsis were randomly assigned to one of two treatment approaches: PMX-F treatment (n = 7) or conventional treatment (n = 7). Plasma endotoxin levels were significantly reduced from 46.6+/-17.8 pg/mI to 8.2+/-2.4 pg/ml, p < 0.01, in patients treated with PMX-F, and serum cardiac troponin T levels were also reduced from 0.62+/-0.30 microg/L to 0.26 = 0.12 microg/L, p < 0.05. Cardiac troponin T levels were unchanged in patients under conventional treatment. These data suggest that cardiac troponin T is indeed elevated in septic patients undergoing hemodialysis and niay reflect subclinical myocardial cell damage. PMX-F is effective in reducing myocardial damage, in part, due to reducing plasma endotoxin levels.