Background: Neurotoxicity of long-term exposure to toluene is known at higher levels than 50 ppm and is suspected at lower levels.

Methods: A cross-sectional study carried out in two printing plants on 129 blue collar workers explored such a low level exposure of toluene. With 231 samples of ambient air, toluene concentration was estimated from 0 to 18 ppm in Plant A (offset) and from 2 to 27 ppm in Plant B (heliogravure). Outside any period of acute exposure, the workers answered a self-administered questionnaire on neurotoxic symptoms, EUROQUEST, and performed six psychometric tests on a computer-assisted version of battery NES.

Results: After adjustment for confounders, we found significant relationships only between present exposure and Digit Span Forwards (DSF) performance (decrement is 1 digit for 40 ppm, P=0.04) and Digit Span Backwards (DSB) performance (decrement is 1 digit for 25 ppm, P=0.01). Neurotoxic symptoms were not significantly correlated with current exposure. No association was found between estimated cumulative exposure and either psychometric performances or neurotoxic symptoms.

Conclusion: In this study, low present exposure levels to toluene were associated with decrements of memory test performances.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ajim.10030DOI Listing

Publication Analysis

Top Keywords

exposure
8
exposure toluene
8
ppm plant
8
neurotoxic symptoms
8
digit span
8
performance decrement
8
decrement digit
8
digit ppm
8
toluene
5
ppm
5

Similar Publications

Background: Proton pump inhibitors (PPI) for gastroesophageal reflux disease (GERD) are associated with a high failure rate. Our uncontrolled feasibility study aimed determining the effect of a transcutaneous electrical stimulation system (TESS) on GERD symptoms and acid exposure time (AET).

Methods: Recruited patients with heartburn and regurgitation.

View Article and Find Full Text PDF

Objective: Patients with uncontrolled gout have few treatment options. Pegloticase lowers serum urate (SU) levels, but antidrug antibodies limit SU-lowering response and increase infusion reaction (IR) risk. Methotrexate (MTX) cotherapy increases pegloticase response rates and lowers IR risk in pegloticase-naïve patients.

View Article and Find Full Text PDF

Comprehensive Analysis Reveals the Potential Diagnostic Value of Biomarkers Associated With Aging and Circadian Rhythm in Knee Osteoarthritis.

Orthop Surg

January 2025

Department of Orthopedics, Tianjin Medical University General Hospital, International Science and Technology Cooperation Base of Spinal Cord Injury, Tianjin Key Laboratory of Spine and Spinal Cord, Tianjin, China.

Objective: Knee osteoarthritis (KOA) is characterized by structural changes. Aging is a major risk factor for KOA. Therefore, the objective of this study was to examine the role of genes related to aging and circadian rhythms in KOA.

View Article and Find Full Text PDF

Deciphering the toxic effects of polystyrene nanoparticles on erythropoiesis at single-cell resolution.

Zool Res

January 2025

Department of Biomedical Informatics, School of Medicine, Pusan National University, Yangsan, Gyeongsangnam-do 50612, Republic of Korea.

Polystyrene nanoparticles pose significant toxicological risks to aquatic ecosystems, yet their impact on zebrafish ( ) embryonic development, particularly erythropoiesis, remains underexplored. This study used single-cell RNA sequencing to comprehensively evaluate the effects of polystyrene nanoparticle exposure on erythropoiesis in zebrafish embryos. validation experiments corroborated the transcriptomic findings, revealing that polystyrene nanoparticle exposure disrupted erythrocyte differentiation, as evidenced by the decrease in mature erythrocytes and concomitant increase in immature erythrocytes.

View Article and Find Full Text PDF

Background: Computed tomography (CT) is the gold standard imaging modality for the assessment of 3D bony morphology but incurs the cost of ionizing radiation exposure. High-resolution 3D magnetic resonance imaging (MRI) with CT-like bone contrast (CLBC) may provide an alternative to CT in allowing complete evaluation of both bony and soft tissue structures with a single MRI examination.

Purpose: To review the technical aspects of an optimized stack-of-stars 3D gradient recalled echo pulse sequence method (3D-Bone) in generating 3D MR images with CLBC, and to present a pictorial review of the utility of 3D-Bone in the clinical assessment of common musculoskeletal conditions.

View Article and Find Full Text PDF