The superior performance of stentless aortic valves with improved left ventricular hypertrophy regression and greater effective orifice area is proven. The Aortech Elan stentless valve (AESV) is a glutraldehyde preserved porcine valve with a pericardial reinforced inflow tract and a scalloped outflow to reduce bulk. We present the early results of AESV implantation at our institution. The first 41 consecutive recipients of the AESV at our unit, between November 1999 and December 2000, were studied. Mean preoperative New York Heart Association functional class (NYHA) status was 3.00 +/- 0.1. Patients requiring a bioprosthesis with suitable anatomy routinely received this implant. The AESV was implanted, either with an interrupted or continuous suture to the inflow tract and a continuous suture to the outflow tract. Transthoracic echocardiography was performed at 6 to 9 weeks after surgery, and aortic transvalvular gradients, flow velocities, and effective orifice areas (EOA) were calculated. In the early postoperative period, two patients with coronary artery disease died of low cardiac output. Echocardiography demonstrated competent valves. At follow-up, one patient was shown to have mild to moderate perivalvular leak with minimal symptoms. Two patients with aortic regurgitation secondary to bacterial endocarditis had no evidence of infection at 3 months after surgery. Mean transvalvular gradient was 6.91 +/- 0.87 mm Hg and mean effective orifice area was 1.18 +/- 0.04 cm(2)/m(2) at a mean of 8.4 weeks after surgery. AESV recipients for native aortic endocarditis were free from infection and regurgitation. The Elan stentless aortic valve demonstrates excellent early hemodynamic results, with very low transvalvular gradients, good flow characteristics and low regurgitation incidence. Ease of implantation is evidenced by favorable ischemic times. This valve may offer an option to homograft in acute aortic endocarditis. Long-term results are awaited.
Download full-text PDF |
Source |
---|
Congenit Heart Dis
August 2015
Department of Cardiothoracic Surgery, Anesthesia and Intensive Care, Skane University Hospital, Lund University, Lund, Sweden.
Objective: Several types of valves and valved conduits have been developed for right ventricular outflow tract reconstruction and yet no one has provided prolonged satisfactory hemodynamic performance. The RVOT Elan is a bioprosthetic heart valve conduit constructed from a vascular graft and a porcine stentless valve indicated specifically for right ventricular outflow tract reconstruction. The present study aimed to evaluate the early clinical and hemodynamic results following implantation of the RVOT Elan in adults and adolescents with congenitally corrected right ventricular outflow tract anomalies requiring reintervention.
View Article and Find Full Text PDFHeart
January 2013
Department of Cardiology, Glenfield Hospital, University Hospitals of Leicester NHS Trust & NIHR Cardiovascular Biomedical Research Unit, University of Leicester, Leicester, UK.
Background: In patients being considered for aortic valve replacement, there remains controversy over which design or tissue offers the best performance. We aimed to evaluate in a single study the haemodynamic performances of five different widely used aortic valve prostheses: stentless porcine xenograft (Elan), stentless bovine pericardium (Pericarbon Freedom), stented porcine xenograft (Aspire), stented bovine pericardium (More) and mechanical (Ultracor). We also compared them with normal aortic valves and stenosed valves of variable severity.
View Article and Find Full Text PDFThorac Cardiovasc Surg
June 2011
Department of Cardiovascular Surgery, Heart Center Brandenburg, Bernau, Germany.
A 59-year-old patient developed endocarditis with coagulase-negative staphylococci after aortic composite graft replacement and pacemaker implantation. She underwent complete pacemaker removal and tricuspid valve reconstruction. Pus was present in and around the aortic graft.
View Article and Find Full Text PDFJ Card Surg
May 2010
Wessex Cardiothoracic Centre, Southampton General Hospital, Southampton, United Kingdom.
Background: The Biovalsalva aortic root prosthesis incorporates an Elan porcine stentless biological aortic valve suspended within a triple-layered vascular conduit with preformed aortic sinuses of Valsalva. This study compared implantation of the Biovalsalva prosthesis with a "handsewn" composite bioprosthetic graft (CE Perimount bovine bioprosthesis anastomosed to a gelatin-impregnated gelweave Dacron graft).
Methods: Between December 2004 and January 2009, 39 patients underwent elective or urgent aortic root replacement (modified Bentall procedure with coronary button reimplantation) using a Biovalsalva (n = 21) or a handsewn bioprosthesis (n = 18) for aortic root dilatation.
Surg Technol Int
January 2010
Division of Cardiac Surgery, European Hospital, Roma, Italy.
Aortic root replacement is the procedure of choice for patients with ascending aortic aneurysms and diseased aortic valve leaflets. The increasing age of patients who undergo aortic root surgery, and data that support the use of a biological aortic valve in the younger population, have significantly increased the need for a composite biological valved conduit. The third-generation Triplextrade (Terumo Vascutek, Renfrewshire, Scotland, UK) Dacron conduit with its three-layer technology, can be stored in glutaraldehyde along with biological prostheses while maintaining a complete blood impermeability.