Background: Therapy employing passive finger flexion and active finger extension with the wrist fixed in flexion is commonly used after flexor tendon repair. However, this method of rehabilitation may not produce full tendon excursion because of buckling of the tendon within its sheath with passive flexion. Studies of cadavera suggest that the use of synergistic wrist and finger motion may improve tendon gliding. The purpose of this study was to assess the effects of passive digital motion, performed with either wrist fixation or synergistic wrist motion, on adhesion and gap formation after flexor tendon repair.

Methods: Sixty-six dogs were randomly allocated to two groups. In each group, two flexor digitorum profundus tendons of one forepaw were partially (80%) lacerated and then repaired with a modified Kessler suture. In each group, a different postoperative therapy (wrist fixation or synergistic motion) was performed twice daily. The dogs were killed at one week, three weeks, or six weeks after surgery, and the repaired tendons were evaluated to determine the adhesion grade and adhesion breaking strength.

Results: The synergistic motion group had a significantly lower adhesion grade and significantly less adhesion breaking strength than the wrist fixation group at three and six weeks (p < 0.05). At one week, there was no significant difference between the two therapy groups (p > 0.05).

Conclusions: Passive digital flexion and extension with synergistic wrist motion was an effective therapy after repair of partial zone-2 lacerations in a canine model.

Download full-text PDF

Source

Publication Analysis

Top Keywords

synergistic wrist
16
wrist motion
12
wrist fixation
12
motion adhesion
8
repair partial
8
flexor digitorum
8
digitorum profundus
8
lacerations canine
8
canine model
8
flexor tendon
8

Similar Publications

High-Performance Mechano-Sensitive Piezoelectric Nanogenerator from Post-Treated Nylon-11,11 Textiles for Energy Harvesting and Human Motion Monitoring.

ACS Appl Mater Interfaces

January 2025

School of Materials Science and Engineering, Henan Key Laboratory of Advanced Nylon Materials and Application, Zhengzhou University, Zhengzhou 450001, China.

Piezoelectric polymer textiles offer distinct advantages in the fabrication of wearable nanogenerators (NGs). One effective strategy to enhance the output capacity of NGs is to modulate the piezoelectric performance of the textiles. This paper focuses on further improving the piezoelectric properties of nylon-11,11 textiles through post-drawing and annealing treatments.

View Article and Find Full Text PDF

Nanocellulose-toughened super-stretchable ionic conductive gel fibers for wearable strain sensors.

Int J Biol Macromol

January 2025

College of Textiles, Donghua University, Shanghai 201620, China; Key Laboratory of Textile Science & Technology, Ministry of Education, College of Textiles, Donghua University, Shanghai, 201620, China. Electronic address:

In recent years, conductive gel materials have attracted extensive attention in the field of flexible electronics because of their excellent elasticity. When constructed as gel fibers, they can adapt to greater deformation, be woven, and be assembled with fabrics to make wearable smart devices without compromising comfort. However, gel fibers reported often exhibit insufficient mechanical properties and poor adaptability to different environment.

View Article and Find Full Text PDF

Objectives: Insufficient sleep is linked to various health issues, while physical activity is a protective measure against chronic diseases. Despite the importance of sleep and physical activity for supporting public health, there remains scant research investigating daily and cumulative associations between objectively measured physical activity and sleep. Understanding the associations of physical activity and sleep behaviors over multiple days may inform the efficacy of interventions to synergistically support both behaviors.

View Article and Find Full Text PDF

Objectives: This study investigated the effects of transcranial direct current stimulation (tDCS) before and during the mirror visual feedback (MVF) on hand grip strength (HGS) and range of motion of the affected hand in children with spastic hemiplegia cerebral palsy (SHCP).

Materials & Methods: Twelve children with SHCP participated in this randomized, crossover, and double-blind study. They were randomly exposed to one of four intervention conditions, including 1) a-tDCS-offline, 2) s-tDCS-offline, 3) a-tDCS-online, and 4) s-tDCS-online, with a one-week interval.

View Article and Find Full Text PDF

Introduction: The use of visual and proprioceptive feedback is a key property of motor rehabilitation techniques. This feedback can be used alone, for example, for vision in mirror or video therapy, for proprioception in focal tendon vibration therapy, or in combination, for example, in robot-assisted training. This Electroencephalographic (EEG) study in healthy subjects explored the distinct neurophysiological impact of adding visual (video therapy), proprioceptive (focal tendinous vibration), or combined feedback (video therapy and focal tendinous vibration) to a motor imagery task.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!