Our purpose was to evaluate and compare the performance of ultra-fast single-shot T2-weighted sequences: echo-planar imaging (EPI) versus half-Fourier single-shot turbo spin-echo (HASTE) and to assess the usefulness of their combined reading. Comparative experiments on a phantom as well as a prospective clinical study in 47 patients were done. Axial images acquired with the following methods were compared: (a) HASTE; (b) segmented HASTE (s-HASTE); (c) single-shot spin-echo EPI (SE-EPI); and (d) gradient-echo EPI (GREEPI). Quantitative and qualitative criteria as well as lesion detectability were analyzed against the "gold standard" fast spin-echo (FSE) sequence. For contrast and contrast-to-noise ratio (CNR) between gray and white matter, GRE-EPI was best. The visibility of small markedly hyperintense lesion was best with HASTE and s-HASTE in the clinical study. Small hyperintense lesions were detected equally well with all four sequences, although all performed significantly worse than FSE. The two HASTE variants were better than the EPIs for the extraaxial lesions. The combination of the GRE-EPI and s-HASTE was judged best, and sometimes superior to the FSE image. HASTE or EPI alone cannot substitute for FSE in the screening evaluation of the brain. However, together, EPI and HASTE could provide comparable diagnostic information to that of FSE because their combination compensates for their individual limitations.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s002340100622DOI Listing

Publication Analysis

Top Keywords

haste
8
epi haste
8
clinical study
8
haste s-haste
8
epi
5
fse
5
comparison epi
4
haste ultra-fast
4
ultra-fast imaging
4
imaging human
4

Similar Publications

Background: When antispasmodics are unavailable, the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER; called BLADE by Siemens Healthineers) or half Fourier single-shot turbo spin echo (HASTE) is clinically used in gynecologic MRI. However, their imaging qualities are limited compared to Turbo Spin Echo (TSE) with antispasmodics. Even with antispasmodics, TSE can be artifact-affected, necessitating a rapid backup sequence.

View Article and Find Full Text PDF

Purpose: To evaluate ferumoxytol-enhanced magnetic resonance angiography (FE-MRA) for assessment of endoleaks in patients with abdominal aortic aneurysms (AAA) and chronic kidney disease (CKD) status post endovascular aneurysm repair (EVAR).

Methods: Of 1854 patients who underwent FE-MRA at a single institution between 03/21/2014 and 08/21/2023, 21 patients with a history of AAA and CKD status post EVAR were retrospectively identified (IRB #13-001341). Multiplanar pre- and post-contrast HASTE, T1-VIBE, and high-resolution breath-held 3D MRA sequences were obtained, where a dose of 4 mg/kg of Ferumoxytol was infused over six minutes.

View Article and Find Full Text PDF

The capacity of recipients to support transferred embryos is a challenge for dairy cattle production systems. This review explores methods for increasing P4 to improve early pregnancy establishment in dairy cattle. A key aspect of P4 supplementation during the critical first weeks of pregnancy is its correlation with successful embryo elongation.

View Article and Find Full Text PDF
Article Synopsis
  • Segmentation of lung structures in medical imaging is important for diagnosing and treating diseases like cystic fibrosis, with neural networks showing better results than traditional methods, but challenges remain with different imaging types and pathologies.
  • This study used deep learning to segment MRI scans from pediatric cystic fibrosis patients, employing the nnU-Net framework and analyzing data from 165 scans across various sequences (BLADE, VIBE, HASTE). The analysis focused on patient variability in disease severity and age.
  • Results indicated high segmentation accuracy (with Dice coefficients around 0.95-0.96) and consistent performance regardless of patient differences, although some issues with segmentation completeness were noted, particularly in the diaphragm area; the model also showed
View Article and Find Full Text PDF

Objectives: To evaluate the feasibility of using dynamic MRI to measure the features of cranial rhythmic impulse (CRI).

Design And Setting: Fifteen healthy participants (9 females and 6 males, aged 25 to 77) underwent dynamic MRI in a sagittal T2 HASTE view at a rate of 0.60 Hz for 30 s.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!