Background: The wide range of closure devices for arterial access sites still leaves room for improvement.

Methods And Results: We report our initial experience with a novel, cost-effective, suture-mediated device (6 French X-PRESS device, X-SITE Medical, Blue Bell, Pennsylvania) for closure of the arterial access site after both diagnostic and therapeutic interventions. A total of 51 consecutive patients are reported. The closure was performed immediately after the procedure. No patient had more than 5,000 U heparin administered during the procedure. The closure device was used in 36 patients (73%) after diagnostic angiography and in 15 patients (27%) after therapeutic intervention. The device could be successfully deployed in 48 patients (94%). In the remaining 3 cases (6%), hemostasis was achieved with standard manual compression without any further event. Immediate total hemostasis was achieved with the device in 44 of 48 patients (92%). Four devices (8%) could not be deployed correctly due to technical problems and the patients needed additional manual compression. The average time to achieve complete hemostasis was 5.5 +/- 3.5 minutes (range, 3-26 minutes). The patients were ambulated after a period of 1.3 +/- 0.4 hours of bedrest (range, 0.8-3.5 hours). Time to possible discharge was 4.2 +/- 3.4 hours (range, 0.9-12.5 hours). One patient experienced a minor complication (hematoma < 6 cm) and was treated with manual compression without clinical sequelae. Telephone follow-up was carried out 2 weeks after deployment and revealed no sequelae.

Conclusion: The 6 French X-PRESS device is safe and effective in providing rapid hemostasis following interventional or diagnostic catheterization procedures. Use of the device is associated with a low rate of complications and facilitates quick hemostasis, mobilization and discharge.

Download full-text PDF

Source

Publication Analysis

Top Keywords

device patients
12
manual compression
12
device
8
closure device
8
patients
8
interventional diagnostic
8
arterial access
8
french x-press
8
x-press device
8
hemostasis achieved
8

Similar Publications

Background: Heart failure (HF) is a chronic, progressive condition where the heart cannot pump enough blood to meet the body's needs. In addition to the daily challenges that HF poses, acute exacerbations can lead to costly hospitalizations and increased mortality. High health care costs and the burden of HF have led to the emerging application of new technologies to support people living with HF to stay well while living in the community.

View Article and Find Full Text PDF

Background: Traditional in-clinic methods of collecting self-reported information are costly, time-consuming, subjective, and often limited in the quality and quantity of observation. However, smartphone-based ecological momentary assessments (EMAs) provide complementary information to in-clinic visits by collecting real-time, frequent, and longitudinal data that are ecologically valid. While these methods are promising, they are often prone to various technical obstacles.

View Article and Find Full Text PDF

Background: Laparoscopic surgery training is a demanding process requiring technical and nontechnical skills. Surgical training has evolved from traditional approaches to the use of immersive digital technologies such as virtual, augmented, and mixed reality. These technologies are now integral to laparoscopic surgery training.

View Article and Find Full Text PDF

: The utilization of intra-aortic balloon pump (IABP) and Impella has been suggested as means of left ventricular unloading in veno-arterial extracorporeal membrane oxygenation (VA-ECMO) patients. This study aimed to assess the local hemodynamic alterations in VA-ECMO patients through simulation analyses. : In this study, a 0D-3D multiscale model was developed, wherein resistance conditions were employed to define the flow-pressure relationship.

View Article and Find Full Text PDF

: This study evaluated changes in selected spatiotemporal and kinematic gait parameters and balance in girls with Adolescent idiopathic scoliosis (AIS) with and without the Chêneau brace. : 15 subjects with scoliosis wearing the Chêneau brace and an equal comparative control group underwent objective gait analysis with the 3D BTS motion caption system. Balance assessment was done with the Kistler platform.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!