For the assessment of myocardial perfusion with cardiac magnetic resonance imaging, different semiquantitative parameters of the first pass signal intensity time curves can be calculated and myocardial perfusion reserve indices can be determined. In this study we evaluated the feasibility of different perfusion parameters and their perfusion reserve indices for the detection of significant coronary artery stenosis. The signal intensity time curves of the first pass of a gadolinium-DTPA bolus injected via a central vein catheter before and after dipyridamole infusion were investigated in 15 patients with single vessel (stenosis > or = 75% area reduction) and five patients without significant coronary artery disease. For the distinction of ischemic and nonischemic myocardial segments, semiquantitative parameters, such as maximal signal intensity, contrast appearance time, time to maximal signal intensity and the steepness of the signal intensity curve's upslope determined by a linear fit, were assessed after correction for the input function. For each parameter a myocardial perfusion reserve index was calculated and cut off values for the detection of significant coronary stenosis were defined. The diagnostic accuracy of each parameter was then examined prospectively in 36 patients with coronary artery disease and compared with coronary angiography. Where as a distinction of ischemic and normal myocardium was possible with myocardial perfusion reserve indices, semiquantitative parameters at rest or after vasodilation alone did not allow such a distinction. The perfusion reserve index calculated from the upslope showed the most significant difference between ischemic and nonischemic myocardial segments (1.19 +/- 0.4 and 2.38 +/- 0.45, p < 0.001) followed by maximum signal intensity, time to maximum signal intensity and contrast apperance time. Sensitivity, specificity and diagnostic accuracy was 87, 82 and 85% for the detection of hypoperfusion induced by significant coronary artery stenoses using the perfusion reserve index calculated from the upslope. The steepness of the first pass signal intensity curve's upslope, determined by a linear fit, is a feasible parameter for the detection of significant coronary artery disease with MR. Based on a myocardial perfusion reserve index of this parameter, ischemic myocardium can be identified with high diagnostic accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s003920170081DOI Listing

Publication Analysis

Top Keywords

perfusion reserve
32
signal intensity
32
myocardial perfusion
24
coronary artery
20
semiquantitative parameters
12
intensity time
12
reserve indices
12
detection coronary
12
artery disease
12
reserve calculated
12

Similar Publications

Insulin plays a key role in metabolic homeostasis. insulin-producing cells (IPCs) are functional analogues of mammalian pancreatic beta cells and release insulin directly into circulation. To investigate the in vivo dynamics of IPC activity, we quantified the effects of nutritional and internal state changes on IPCs using electrophysiological recordings.

View Article and Find Full Text PDF

Anomalous aortic origin of a coronary artery (AAOCA) comprises a set of rare congenital abnormalities in the origin or path of the coronary arteries with highly variable clinical implications. This is a pilot feasibility study where we investigated the influence of the anomalous coronary artery inlet architecture on coronary perfusion using coronary blood flow computational simulations to help predict the risk for coronary ischemia in patients with anomalous aortic origin of the right coronary artery (AAORCA) with these types of anomalous coronary artery inlet architectures. We developed a protocol for generating 3D models of patient coronary artery anatomies from an IRB-approved dataset of cardiac CT images of patients with AAORCA at our institution.

View Article and Find Full Text PDF

Background And Objectives: Although previous trials have established the efficacy and safety of endovascular thrombectomy (EVT) in large ischemic core strokes, most of them excluded patients with extracranial internal carotid artery (e-ICA) occlusion. We aimed to compare outcomes in patients with e-ICA occlusion and large ischemic core infarcts treated with EVT vs medical management (MM).

Methods: This was a secondary analysis of the SELECT2 trial, a randomized controlled trial conducted at 31 international sites.

View Article and Find Full Text PDF

Background: The fluorescent dye indocyanine green (ICG) has been used to identify anatomical structures intraoperatively in coronary artery bypass grafting (CABG). This study aimed to evaluate the feasibility of using ICG to assess graft patency and territorial distribution of myocardial reperfusion during CABG.

Methods: Porcine arrested hearts (n = 18) were used to evaluate territorial distribution of native coronary arteries and of a coronary bypass constructed with porcine saphenous vein graft (SVG) using ICG.

View Article and Find Full Text PDF

Objectives: To conduct a meta-analysis of the diagnostic performance of non-contrast magnetic resonance pulmonary angiography (NC-MRPA) and ventilation-perfusion (V/Q) scintigraphy for the detection of acute pulmonary embolism (PE).

Materials And Methods: Systematic searches of electronic databases were conducted from 2000 to 2024. Primary outcomes were per-patient sensitivity and specificity of NC-MRPA and V/Q scintigraphy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!