Methods based on magnetic resonance imaging for the measurement of three-dimensional distributions of radiation dose are highly developed. However, relatively little work has been done on optical computed tomography (OCT). This paper describes a new OCT scanner based on a broad beam light source and a two-dimensional charge-coupled device (CCD) detector. A number of key design features are discussed including the light source; the scanning tank, turntable and stepper motor control; the diffuser screen onto which images are projected and the detector. It is shown that the non-uniform pixel sensitivity of the low-cost CCD detector used and the granularity of the diffuser screen lead to a serious ring artefact in the reconstructed images. Methods are described for eliminating this. The problems arising from reflection and refraction at the walls of the gel container are explained. Optical ray-tracing simulations are presented for cylindrical containers with a variety of radii and verified experimentally. Small changes in the model parameters lead to large variations in the signal intensity observed in the projection data. The effect of imperfect containers on data quality is discussed and a method based on a 'correction scan' is shown to be successful in correcting many of the related image artefacts. The results of two tomography experiments are presented. In the first experiment, a radiochromic Fricke gel sample was exposed four times in different positions to a 100 kVp x-ray beam perpendicular to the plane of imaging. Images of absorbed dose with slice thickness of 140 microm were acquired. with 'true' in-plane resolution of 560 x 560 microm2 at the edge of the 72 mm field of view and correspondingly higher resolution at the centre. The nominal doses measured correlated well with the known exposure times. The second experiment demonstrated the well known phenomenon of diffusion in the dosemeter gels and yielded a value of (0.12 +/- 0.02) mm2 s(-1) for the diffusion coefficient of the xylenol orange/iron complex. Finally, the overall implications of the above findings for dosimetry using OCT are discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/46/12/309DOI Listing

Publication Analysis

Top Keywords

radiation dose
8
light source
8
ccd detector
8
diffuser screen
8
ccd-based optical
4
optical scanner
4
scanner high-resolution
4
high-resolution imaging
4
imaging radiation
4
dose distributions
4

Similar Publications

Ra, Th, and K levels in various foods frequently consumed by Egyptians were determined using a gamma-ray spectrometer based on the germanium detector (HPGe). Activity concentrations of Ra, Th, and K were in the range of < 0.10 to 0.

View Article and Find Full Text PDF

The impact of three-dimensional (3D) dose delivery accuracy of C-arm linacs on the planning target volume (PTV) margin was evaluated for non-coplanar intracranial stereotactic radiosurgery (SRS). A multi-institutional 3D starshot test using beams from seven directions was conducted at 22 clinics using Varian and Elekta linacs with X-ray CT-based polymer gel dosimeters. Variability in dose delivery accuracy was observed, with the distance between the imaging isocenter and each beam exceeding 1 mm at one institution for Varian and nine institutions for Elekta.

View Article and Find Full Text PDF

Patch-based dual-domain photon-counting CT data correction with residual-based WGAN-ViT.

Phys Med Biol

January 2025

Electrical and Computer Engineering, University of Massachusetts Lowell, Ball Hall, 1 University Ave, Lowell, Massachusetts, 01854, UNITED STATES.

Objective: X-ray photon-counting detectors (PCDs) have recently gained popularity due to their capabilities in energy discrimination power, noise suppression, and resolution refinement. The latest extremity photon-counting computed tomography (PCCT) scanner leverages these advantages for tissue characterization, material decomposition, beam hardening correction, and metal artifact reduction. However, technical challenges such as charge splitting and pulse pileup can distort the energy spectrum and compromise image quality.

View Article and Find Full Text PDF

Application value of split-bolus contrast injection combined with dual-energy CT scanning technology in pediatric CTU imaging.

Eur J Radiol

January 2025

Department of Radiology Children's Hospital of Chongqing Medical University, National Clinical Research Center for Child Health and Disorders, Ministry of Education Key Laboratory of Child Development and Disorders, Chongqing Key Laboratory of Child Neurodevelopment and Cognitive Disorders, China. Electronic address:

Objective: To explore the clinical value of combining split-bolus contrast injection with dual-energy CT(DECT) scanning technology in pediatric computed tomography urography (CTU) imaging.

Methods: A total of 128 children aged 0-17 years were prospectively selected and randomly assigned to three groups: A, B, and C. For Group A, a high-pitch flash mode was employed, where a single bolus of contrast agent was followed by four-phase scanning (noncontrast, cortex, medulla, and excretory phases).

View Article and Find Full Text PDF

: The aim of this study was to investigate the effect of substrate - polycaprolactone (PCL)-based porous membrane modified with rosmarinic acid (RA), (PCL-RA) and to determine the optimal values of low field laser irradiation (LLLT) as stimulators of biological response of RAW 264.7 macrophages. : The porous polymer membrane was obtained by the phase inversion method, the addition of rosmarinic acid was 1%wt.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!