The aim of this study was to demonstrate that dose reduction and constant image quality can be achieved by adjusting X-ray dose to patient size. To establish the relation between patient size, image quality and dose we scanned 19 patients with reduced dose. Image noise was measured. Four radiologists scored image quality subjectively, whereby a higher score meant less image quality. A reference patient diameter was determined for which the dose was just sufficient. Then 22 patients were scanned with the X-ray dose adjusted to their size. Again, image noise was measured and subjective image quality was scored. The dose reduction compared with the standard protocol was calculated. In the first group the measured noise was correlated to the patient diameter (rho=0.78). This correlation is lost in the second group (rho=-0.13). The correlation between patient diameter and subjective image quality scores changes from rho=0.60 (group 1) to rho=-0.69 (group 2). Compared with the standard protocol, the dose was reduced (mean 28%, range 0-76%) in 19 of 22 patients (86%). Dose reduction and constant noise can be achieved when the X-ray dose is adjusted to the patient diameter. With constant image noise the subjective image quality increases with larger patients.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s003300101039 | DOI Listing |
Invest Radiol
January 2025
From the Departments of Radiology (J.F.H., S.Y.C., J.-P.G., J.S., P.N., S.B.R., T.M.G.), Biomedical Engineering (S.B.R., T.M.G.), Medical Physics (S.Y.C., S.B.R., T.M.G.), Medicine (S.B.R.), and Emergency Medicine (S.B.R.), University of Wisconsin-Madison, WI; and Department of Diagnostic and Interventional Radiology (J.F.H., J.-P.G.), University Hospital Würzburg, Würzburg, Germany.
Rationale And Objectives: Pulmonary magnetic resonance angiography (MRA) is an imaging method with proven utility for the exclusion of pulmonary embolism and avoids the need for ionizing radiation and iodinated contrast agents. High-relaxivity gadolinium-based contrast agents (GBCAs), such as gadopiclenol, can be used to reduce the required gadolinium dose for pulmonary MRA. The aim of this study was to compare the contrast enhancement performance of gadopiclenol with an established gadobenate dimeglumine-enhanced pulmonary MRA protocol.
View Article and Find Full Text PDFInvest Radiol
January 2025
From the Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany (A. Schwarz, A. Simon, A.M.); Siemens Healthineers AG, Forchheim, Germany (A. Schwarz, C.H., J.D., A. Simon); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (F.K.W., S.G., M.S.); and Institut for Radiology, Pediatric and Neuroradiology, Helios Hospital, Schwerin, Germany (H.-J.R.).
Objective: Respiratory motion can affect image quality and thus affect the diagnostic accuracy of CT images by masking or mimicking relevant lung pathologies. CT examinations are often performed during deep inspiration and breath-hold to achieve optimal image quality. However, this can be challenging for certain patient groups, such as children, the elderly, or sedated patients.
View Article and Find Full Text PDFACS Nano
January 2025
Department of Mechanical Engineering, University of California at Riverside, Riverside, California 92521, United States.
Sensing light's polarization and wavefront direction enables surface curvature assessment, material identification, shadow differentiation, and improved image quality in turbid environments. Traditional polarization cameras utilize multiple sensor measurements per pixel and polarization-filtering optics, which result in reduced image resolution. We propose a nanophotonic pipeline that enables compressive sensing and reduces the sampling requirements with a low-refractive-index, self-assembled optical encoder.
View Article and Find Full Text PDFAnn Med
December 2025
Department of Joint and Sports Medicine, Zhongnan Hospital, Wuhan University, Wuhan, China.
As life expectancy among patients infected with the human immunodeficiency virus (HIV) increases, a growing number of complications have been observed. This population displays an elevated risk of ischemic necrosis of the femoral head in comparison to the general population, which may be attributed to HIV infection, antiretroviral medication use, and hormone application. Patients infected with the human immunodeficiency virus (HIV) who also have necrosis of the femoral head tend to present at an earlier age, with a rapid disease progression and a high incidence of bilateral onset.
View Article and Find Full Text PDFJAMA Otolaryngol Head Neck Surg
January 2025
Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee.
Importance: Airway stenosis is a rare but debilitating disorder that significantly degrades the quality of life in affected patients. Treatments are primarily surgical, and disease management lacks established medical therapies. The North American Airway Collaborative held its third symposium at The Johns Hopkins Hospital in Baltimore, Maryland, on April 15, 2024, focused on strategies to advance the care of these patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!