The groundwater in Bayingnormen (Ba Men), located in Central West Inner Mongolia, China, is naturally contaminated with arsenic at concentrations ranging from 50 microg/L to 1.8 mg/L. Various adverse health effects in this region, including cancer, have been linked to arsenic exposure via drinking water. A pilot study was undertaken to evaluate frequencies of micronuclei (MN), as measures of chromosomal alterations, in multiple exfoliated epithelial cell types from residents of Ba Men chronically exposed to arsenic via drinking water. Buccal mucosal cells, airway epithelial cells in sputum, and bladder urothelial cells were collected from 19 residents exposed to high levels of arsenic in drinking water (527.5 +/- 24 microg/l), and from 13 control residents exposed to relatively low levels of arsenic in drinking water (4.4 +/- microg/L). Analytical results from these individuals revealed that MN frequencies in the high-exposure group were significantly elevated to 3.4-fold over control levels for buccal and sputum cells, and to 2.7-fold over control for bladder cells (increases in MN frequency significant at p < .001 for buccal cells; p < .01 for sputum cells; p < .05 for bladder cells). When smokers were excluded from high-exposure and control groups the effects of arsenic were observed to be greater, although only in buccal and sputum cells; approximately 6-fold increases in MN frequency occurred in these tissues. The results indicate that residents of Ba Men chronically exposed to high levels of arsenic in drinking water reveal evidence of genotoxicity in multiple epithelial cell types; higher levels of induced MN were observed in buccal and sputum cells than in bladder cells.

Download full-text PDF

Source
http://dx.doi.org/10.1080/152873901753215939DOI Listing

Publication Analysis

Top Keywords

drinking water
24
arsenic drinking
20
sputum cells
16
cells
12
chronically exposed
12
levels arsenic
12
buccal sputum
12
bladder cells
12
exfoliated epithelial
8
epithelial cells
8

Similar Publications

MC-LR induces and exacerbates Colitis in mice through the JAK1/STAT3 pathway.

J Toxicol Environ Health A

January 2025

Hunan Province Key Laboratory of Typical Environmental Pollution and Health Hazards, School of Public Health, University of South China, Hengyang, China.

Inflammatory bowel disease (IBD) is a complex gastrointestinal disorder attributed to genetic and environmental factors. Microcystin-leucine-arginine (MC-LR) is an environmental toxin that accumulates in the gut and produces intestinal damage. The aim of this study was to investigate the effects of exposure to MC-LR on development and progression of IBD as well examine the underlying mechanisms of microcystin-initiated tissue damage.

View Article and Find Full Text PDF

K2 channel positive modulation reduces alcohol drinking in female C57BL/6J mice.

Alcohol

January 2025

Department of Neuroscience, Charleston Alcohol Research Center, Medical University of South Carolina, 70 President Street, Drug Discovery Building, Charleston, SC 29425. Electronic address:

Although men have historically exhibited higher levels of alcohol use disorder (AUD) diagnosis, the gap between men and women has been diminishing quickly. Preclinical screening for pharmacological treatments for AUD has typically focused solely on males, ignoring the possibility that males and females may differ mechanistically for the same behavioral phenotype. To ensure the efficacy of treatment targets across the sexes, it is crucial to study the pharmacological effects of AUD treatments in males and females.

View Article and Find Full Text PDF

Monitoring of genotoxic chemicals released into the water cycle or formed through transformation processes is critical to prevent harm to human health. The development of the high-performance thin-layer chromatography (HPTLC)-umu bioassay combines sample separation and detection of genotoxic substances in the low ng/L concentration range. In this study, raw, process, and drinking water samples from 11 different waterworks in Germany were analyzed using the HPTLC-umu.

View Article and Find Full Text PDF

Riverbank filtration is a cost-effective and efficient method for drinking water production, using the natural filtration capacity of the river gravelbed. Removal efficiency for organic micropollutants (OMP) in field studies is generally calculated by comparing the concentrations measured in surface water and in the wells either on the same day or with a shift of fixed time interval, neither of which can account for the variability of surface water quality and travel time in the aquifer. The present study proposes a novel method based on travel time distribution determined by a numerical transport model with a hypothesis that it will provide more reliable estimate for OMP removal.

View Article and Find Full Text PDF

Unveiling significant regrowth and potential risk of nontuberculous mycobacteria in hospital water supply system.

Water Res

January 2025

Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo 113-8656, Japan; Research Center for Advanced Science and Technology, The University of Tokyo, 4-6-1, Komaba, Meguro, Tokyo 153-8904, Japan. Electronic address:

The health burden of waterborne nontuberculous mycobacteria (NTM) is a rising concern. While the water supply systems can serve as a potential reservoir for NTM, their abundance, diversity, and transmission pathways remain unknown. This study aimed to characterize the prevalence and regrowth of NTM in building water supply system in a hospital where many M.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!