A case of "boomerang" bullet ricochet.

Int J Legal Med

Institute of Legal Medicine, University of Münster, Germany.

Published: October 2001

A .375 Holland & Holland Magnum Winchester Fail Safe bullet was fired against a steel plate. The big-game hunting bullet (17.4 g, approx. 810 m/s) has a solid copper-alloy hollow point design including a lead core limited to the rear portion. The range of firing was 20 m and the angle of impact was 90 degrees. A large fragment (10.9 g) consisting of the main part of the copper portion was deformed in a peculiar manner similar to a tube or ring and wounded the left hand of the person shooting. The unique fragment trajectory strictly against the line of fire and the velocity sufficient to shatter bone after a distance of 20 m can be explained by an extraordinary deformation mechanism. Unlike in tissue, the high resistance of the steel plate caused the lead core in the rear of the bullet to move forward perforating the central copper barrier behind the hollow point cavity. Thus, the peculiar fragment was created. The subsequent backwards acceleration of the ring-like fragment was probably caused by the partly elastic impact of the copper-alloy portion against the hard steel plate. Due to the perpendicular impact resulting in a centric and symmetrical deformation, the fragment moved in a direction exactly backwards along the original line of fire.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s004140000148DOI Listing

Publication Analysis

Top Keywords

steel plate
12
hollow point
8
lead core
8
fragment
5
case "boomerang"
4
bullet
4
"boomerang" bullet
4
bullet ricochet
4
ricochet 375
4
375 holland
4

Similar Publications

Due to the uncertainty of material properties of plate-like structures, many traditional methods are unable to locate the impact source on their surface in real time. It is important to study the impact source-localization problem for plate structures. In this paper, a data-driven machine learning method is proposed to detect impact sources in plate-like structures and its effectiveness is tested on three plate-like structures with different material properties.

View Article and Find Full Text PDF

Application of high-heat input welding on high-tensile strength steels causes deterioration of mechanical properties of the welded joint, due to softening and grain coarsening in the heat-affected zone (HAZ). In this study, low-heat input narrow-gap hot-wire laser welding was applied to 12 mm thick 780 MPa-class high-tensile strength steel plate. Conditions were optimized based on microstructural observations of joints produced at various welding speeds.

View Article and Find Full Text PDF

Structural design and safety performance of a novel high-strength steel lightweight guardrail.

PLoS One

January 2025

Key Laboratory of Road and Traffic Engineering of Ministry of Education, Tongji University, Shanghai, China.

Highway guardrails are critical safety infrastructure along roadways, designed to redirect vehicles back into their lanes and facilitate a gradual deceleration to a complete stop. Traditional highway steel guardrails exhibit significant limitations, including inadequate energy absorption, susceptibility to corrosion, and an increased risk of vehicles leaving the roadway during severe collisions. Furthermore, the production and transportation of these guardrails contribute to substantial carbon emissions and environmental pollution.

View Article and Find Full Text PDF

Objective: To investigate the effects of bone density, plate bending degree and proximal screw type on the stress fracture of clavicle hook.

Methods: Three sows weighing between 45 and 50 kg were selected, from which a total of 40 rivs were collected. The 15 ribs of sows were divided into 3 groups according to bone density and bone hardness with 5 rivs in each group.

View Article and Find Full Text PDF

Objective: To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).

Methods: Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!