Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To assess the luminal morphology of the extracranial internal carotid artery at three-dimensional (3D) computed tomographic (CT) angiography and how this factor affects measurement of maximum carotid arterial stenoses at conventional intraarterial digital subtraction angiography (DSA).
Materials And Methods: Prospectively, conventional intraarterial DSA and 3D CT angiography were performed in 42 carotid arteries in 21 patients with suspected carotid artery disease. The longest axis length-perpendicular axis length (L/P) ratios of the arterial lumen on the cross-sectional images at the most stenotic area and distal nonstenotic area were analyzed by acquiring multiplanar reconstruction (MPR) images at 3D CT angiography. The maximum stenosis was measured at each modality with North American Symptomatic Carotid Endarterectomy Trial criteria.
Results: The L/P ratios in the most stenotic areas ranged from 1.0 to 3.2 (mean, 1.5 +/- 0.5 [SD]). The mean difference in maximum percentage of stenosis between the two modalities for L/P ratios of 2.0 or greater was significantly greater than that for L/P ratios of less than 1.5 (P < .05). Three carotid arteries with 70%-99% stenosis, with grades determined only with 3D CT angiography, had L/P ratios of 2.0 or greater.
Conclusion: On MPR images at 3D CT angiography, the lumen of extracranial internal carotid artery stenosis showed a wide range of shapes. When a carotid artery has a high L/P ratio, the luminal morphology of the carotid artery stenosis may affect the assessment of maximum stenosis of the internal carotid artery at conventional DSA.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1148/radiol.2213001746 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!