A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Induction of labor in women with previous cesarean section using the double balloon device. | LitMetric

Induction of labor in women with previous cesarean section using the double balloon device.

Acta Obstet Gynecol Scand

Department of Obstetrics and Gynecology, Western Galilee Medical Center, Nahariya, Israel 22100.

Published: November 2001

Background And Methods: To evaluate the efficacy and safety of labor induction by the double balloon device in women with previous cesarean section. Induction of labor was carried out in 37 women with previous cesarean section for various indications. All the inductions of labor were performed using the Atad double balloon device (ARD).

Results: Cervical ripening (Bishop scores above 5) was achieved in 82.3% of the induced women with subsequent vaginal delivery in 78.6% and repeat cesarean section in 22.3%. An important observation of the results was the chances to achieve a vaginal delivery according to the second Bishop score that was recorded 12 hours following the insertion of the device. When the second was above 5 the chances for vaginal delivery were 79.4%. The mean time from removal of the device to delivery was 10.8 hours. No complications were noted using the device.

Conclusions: The double balloon device appears to be a safe and effective method of inducing labor in women with a previous lower segment cesarean section. Wide scale studies and further use of the device for induction of labor in women who have had previous cesarean sections are warranted.

Download full-text PDF

Source
http://dx.doi.org/10.1034/j.1600-0412.2001.801114.xDOI Listing

Publication Analysis

Top Keywords

women previous
20
previous cesarean
16
double balloon
16
balloon device
16
induction labor
12
labor women
12
vaginal delivery
12
device
7
women
6
cesarean
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!