In treatment planning for conformal radiotherapy, it is possible to attain high accuracy in contouring the outline of the target volume and organs at risk by giving contrast agents (CAs) during the CT scan. In order to calculate the dose from the CT scans, Hounsfield units (HUs) are converted into the parameters of a standard set of tissues with given atomic composition and density. Due to the high atomic number of contrast media, high HU values are obtained during CT scanning. The Helax treatment planning system, for instance, erroneously takes them for high density tissue. This misinterpretation results in high absorption of high-energy photon beams and thus affects the dose calculation significantly. A typical bolus diameter of 3 cm and HU values of 1,400 cause an overdose of up to 7.4% and 5.4% for 6 MV and 25 MV photon beams, respectively. However, since the CA concentration and its expansion are rather low the effect on dose calculation in treatment planning is negligible.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/0031-9155/46/10/308 | DOI Listing |
Neurosurg Rev
January 2025
Department of Neurosurgery, Mount Sinai Hospital, Icahn School of Medicine, New York City, NY, USA.
Currently, the World Health Organization (WHO) grade of meningiomas is determined based on the biopsy results. Therefore, accurate non-invasive preoperative grading could significantly improve treatment planning and patient outcomes. Considering recent advances in machine learning (ML) and deep learning (DL), this meta-analysis aimed to evaluate the performance of these models in predicting the WHO meningioma grade using imaging data.
View Article and Find Full Text PDFArch Orthop Trauma Surg
January 2025
Department of Orthopaedic Surgery, University Hospital centre (Saint Etienne), Avenue Albert Raimond, Saint-priest-en-Jarez, 42270, France.
Introduction: Total knee arthroplasty (TKA) in valgus knees is challenging. Optimal ligament balance, implant neutral or moderate valgus alignment are crucial but conventional instrumentations usually lead to outliers. Robotic arm assisted TKA (RATKA) advantages could answer this challenge.
View Article and Find Full Text PDFEur J Nucl Med Mol Imaging
January 2025
A*STAR Skin Research Labs (A*SRL), Agency for Science, Technology and Research (A*STAR), 31 Biopolis Way, #07-01, Nanos, Singapore, 138669, Republic of Singapore.
Purpose: Basal Cell Carcinoma (BCC), the most common subtype of non-melanoma skin cancers (NMSC), is prevalent worldwide and poses significant challenges due to their increasing incidence and complex treatment considerations. Existing clinical approaches, such as Mohs micrographic surgery, are time-consuming and labour-intensive, requiring meticulous layer-by-layer excision and examination, which can significantly extend the duration of the procedure. Current optical imaging solutions also lack the necessary spatial resolution, penetration depth, and contrast for effective clinical use.
View Article and Find Full Text PDFInt J Oral Maxillofac Surg
January 2025
Division of Maxillofacial Surgery, Department of Surgery, AZ Sint-Jan Brugge AV, Bruges, Belgium; Oral and Maxillofacial Surgery Unit, Division of Surgery, Barzilai Medical Center, Affiliated to Ben-Gurion University of the Negev, Ashkelon, Israel.
Antegonial notching can occur after bilateral sagittal split osteotomy (BSSO) and may lead to unpleasant aesthetic outcomes in both young and older patients. This clinical study presents a new concept to potentially overcome this problem and describes the workflow. Beta-tricalcium phosphate patient-specific gap implants (β-TCP gap-PSIs) are biocompatible and resorbable bone grafts that are placed in the space of the osteotomy gap during orthognathic procedures; they are virtually planned and printed in 3D.
View Article and Find Full Text PDFBackground: Reproductive life planning is key, now that people with cystic fibrosis (pwCF) may live into their 60s. This study explores contraceptive use, pregnancy trends, and whether concomitant cystic fibrosis transmembrane conductance regulator (CFTR) modulator therapy reduces contraceptive effectiveness.
Methods: Females with CF aged 18-45 years from 10 U.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!