Exposure of arctic field scientists to ultraviolet radiation evaluated using personal dosimeters.

Photochem Photobiol

British Antarctic Survey High Cross, Madingley Road, Cambridge CB3 0ET, UK.

Published: October 2001

During July 2000 we used an electronic personal dosimeter (X-2000) and a biological dosimeter (Deutsches Zentrum für Luft- und Raumfahrt: Biofilm) to characterize the UV radiation exposure of arctic field scientists involved in biological and geological fieldwork. These personnel were working at the Haughton impact structure on Devon Island (75 degrees N) in the Canadian High Arctic under a 24 h photoperiod. During a typical day of field activities under a clear sky, the total daily erythemally weighted exposure, as measured by electronic dosimetry, was up to 5.8 standard erythemal dose (SED). Overcast skies (typically 7-8 okta of stratus) reduced exposures by a mean of 54%. We estimate that during a month of field activity in July a typical field scientist at this latitude could potentially receive approximately 80 SED to the face. Because of body movements the upper body was exposed to a UV regimen that often changed on second-to-second time-scales as assessed by electronic dosimetry. Over a typical 10 min period on vehicle traverse, we found that erythemal exposure could vary to up to 87% of the mean exposure. Time-integrated exposures showed that the type of outdoor field activities in the treeless expanse of the polar desert had little effect on the exposure received. Although absolute exposure changed in accordance with the time of day, the exposure ratio (dose received over horizontal dose) did not vary much over the day. Under clear skies the mean exposure ratio was 0.35 +/- 0.12 for individual activities at different times of the day assessed using electronic dosimetry. Biological dosimetry showed that the occupation was important in determining daily exposures. In our study, scientists in the field received an approximately two-fold higher dose than individuals, such as medics and computer scientists, who spent the majority of their time in tents.

Download full-text PDF

Source
http://dx.doi.org/10.1562/0031-8655(2001)074<0570:eoafst>2.0.co;2DOI Listing

Publication Analysis

Top Keywords

electronic dosimetry
12
exposure
9
exposure arctic
8
arctic field
8
field scientists
8
field activities
8
assessed electronic
8
exposure ratio
8
field
7
scientists
4

Similar Publications

Purpose: This study evaluated beam quality and radiation dosimetry of a CT scanner equipped with a novel detector and filtration technology called PureVision Optics (PVO). PVO features miniaturized electronics, a detector cut with microblade technology, and increased filtration in order to increase x-ray detection and reduce image noise.

Methods: We assessed the performance of two similar 320-detector CT scanners: one equipped with PVO and one without.

View Article and Find Full Text PDF

Purpose: This study evaluates the feasibility of utilizing robotic-assisted bronchoscopy with cone beam computed tomography (RB-CBCT) platform to perform low-dose-rate brachytherapy implants (LDR-BT) in a mechanically ventilated human cadaveric model. Post-implant dosimetry was compared to standard stereotactic body radiation therapy plans (SBRT).

Materials And Methods: The RB-CBCT platform was used to place inert LDR-BT seeds into mechanically ventilated human cadavers with percutaneously injected pseudotumors.

View Article and Find Full Text PDF

Visible light has been considered to have minimal impact on the skin. However, the increasing use of electronic devices has led to a significant increase in exposure to visible light, especially blue light. We measured the irradiance (mW/cm) and estimated dose (J/cm) of visible light and blue light emitted from various electronic devices including smartphones, tablets and computers.

View Article and Find Full Text PDF

One of the most problematic goals for radiation safety during spaceflight is an assessment of additional doses received by astronauts during extravehicular activity (EVA). The Pille-ISS thermoluminescent dosimeter developed by the predecessor of the Hungarian Research Network (HUN-REN) Centre for Energy Research (Budapest, Hungary) is designed for the routine dose measurements not only inside the spacecraft compartments, but also for personal dosimetric control for EVA. During almost two decades of the International Space Station (ISS) operation, the unique set of 131 EVA doses were recorded in different conditions, such as: solar activity, ISS trajectory along the South Atlantic Anomaly (SAA), and shielding conditions provided by two kinds of spacesuits: the Extravehicular Mobility Unit (EMU) and Orlan.

View Article and Find Full Text PDF

Space missions have revealed certain disincentive factors of this unique environment, such as microgravity, cosmic radiation, etc., as the aerospace industry has made substantial progress in exploring deep space and its impacts on human body. Galactic cosmic radiation (GCR), a form of ionizing radiation, is one of those environmental factors that has potential health implications and, as a result, may limit the duration - and possibly the occurrence - of deep-space missions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!