A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of heterogeneous and homogeneous radioactivity flow detectors for simultaneous profiling and LC-MS/MS characterization of metabolites. | LitMetric

Comparison of heterogeneous and homogeneous radioactivity flow detectors for simultaneous profiling and LC-MS/MS characterization of metabolites.

J Pharm Biomed Anal

Division of Drug Metabolism, Department of Pharmacokinetics, Dynamics and Metabolism, Pfizer Global Research and Development-Ann Arbor, MI 48105, USA.

Published: January 2002

Methods for simultaneous liquid chromatography-radioactivity monitor (LC-RAM) metabolite profiling and LC-tandem mass spectrometry (MS/MS) characterization of metabolites are described. Profiling and characterization of metabolites from three drug candidates from different therapeutic areas were compared using in-line heterogeneous LC-RAM-MS/MS and homogeneous LC-RAM-MS/MS methods. Although comparison shows that simultaneous metabolite profiling and characterization can be achieved using either heterogeneous or homogeneous-LC-RAM-MS/MS systems, a homogeneous system has the advantage in the following aspects, (1) sensitivity; (2) ease of method transfer; (3) less peak broadening problems due to the drug or metabolites adhering to the RAM cell; (4) accuracy in quantitation of the metabolites; and (5) the ability to load larger volumes of unprocessed biological fluids. Furthermore, the study shows that some of the possible metabolites that do not ionize well with electrospray ionization (ESI) and eluded detection by heterogeneous-LC-RAM detection could be very easily detected and characterized using a homogeneous-LC-RAM-MS/MS system.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0731-7085(01)00547-7DOI Listing

Publication Analysis

Top Keywords

characterization metabolites
12
metabolite profiling
8
profiling characterization
8
metabolites
6
comparison heterogeneous
4
heterogeneous homogeneous
4
homogeneous radioactivity
4
radioactivity flow
4
flow detectors
4
detectors simultaneous
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!