Risk factors for congenital umbilical hernia in German Fleckvieh.

Vet J

Institute of Animal Breeding and Genetics, School of Veterinary Medicine Hannover, Bünteweg 17p, 30559 Hannover, Germany.

Published: November 2001

Risk factors for congenital umbilical hernias were investigated in German Fleckvieh calves up for sale at livestock markets. Data from 53,105 calves were collected from 77 livestock auctions in 1996 and 1997. The overall incidence of congenital umbilical hernia was 1.8%. A significant influence on incidence was exerted by the sex of the calf, the occurrence of multiple births, the market place/market date, the sire and the sire line. The proportion of Red Holstein blood in the calf, the dam's lactation number, gestation length, 305 day milk performance and the herd milk level were not significant factors. Herdmate averages for calves differed significantly in their incidence. Heritability estimates on the liability scale for congenital umbilical hernia were about 0.4 and progeny groups of sires at risk for congenital umbilical hernia were in the range 0.1% to 14.2%. The segregation pattern could not be explained either by an autosomal recessive or by an autosomal dominant monogenic model. It seems likely that more than one gene locus is involved in the underlying genetic mechanism. Breeders should be aware of the genetic implications of congenital umbilical hernias.

Download full-text PDF

Source
http://dx.doi.org/10.1053/tvjl.2000.0567DOI Listing

Publication Analysis

Top Keywords

congenital umbilical
24
umbilical hernia
16
risk factors
8
factors congenital
8
german fleckvieh
8
umbilical hernias
8
congenital
6
umbilical
6
hernia
4
hernia german
4

Similar Publications

Background: Neonates with congenital anomalies frequently require perioperative allogeneic red blood cell (RBC) transfusion. Whole cord blood for autologous transfusion to neonates may provide an alternative RBC source, but whether sufficient volumes can be collected after delayed cord clamping to reduce allogeneic RBC requirements is unknown.

Study Design And Methods: Inclusion criteria were mothers delivering a viable infant >34 weeks' gestation.

View Article and Find Full Text PDF

Balloon atrioseptostomy for transposition of the great arteries in Europe: characteristics and outcomes.

Rev Esp Cardiol (Engl Ed)

January 2025

Pediatric Cardiology Department, M3C National reference center, Hospital Necker- Enfants Malades, Assistance Publique-Hôpitaux de Paris, University Paris Cité, Paris, France.

Introduction And Objectives: Balloon atrial septostomy (BAS) improves oxygenation in neonates with transposition of the great arteries (TGA) and restrictive foramen ovale. Currently, there is a global shortage of dedicated BAS catheters, while new unmarked catheters have recently become available at some European centers. This study aimed to characterize BAS outcomes using the currently available BAS catheters in Europe.

View Article and Find Full Text PDF

Background: ALG8-congenital disorder of glycosylation (ALG8-CDG) is a rare inherited metabolic disorder leading to severe multisystem manifestations, with no reported prenatal patients to date.

Methods: We describe two fetuses from a single family with ALG8-CDG presenting with prenatal hydrops, undergoing comprehensive prenatal ultrasound, umbilical cord blood biochemistry, autopsy, placental pathology, and genetic testing.

Results: Prenatal ultrasound revealed fetal hydrops, skeletal anomalies, cardiac developmental abnormalities, cataracts, echogenic kidneys and bowel, oligohydramnios, choroid plexus cysts, and intrauterine growth restriction.

View Article and Find Full Text PDF

Comparison of umbilical artery pulsatility index reference ranges.

Ultrasound Obstet Gynecol

January 2025

Department of Obstetrics and Gynecology, Morsani College of Medicine, University of South Florida, Tampa, FL, USA.

Objective: To compare the accuracy of four published reference standards for the umbilical artery pulsatility index (UA-PI) in predicting small-for-gestational age (SGA), adverse neonatal outcomes and obstetric complications in pregnancies at risk for fetal growth restriction.

Methods: This was a secondary analysis of a prospective study of singleton pregnancies that underwent fetal growth assessment by ultrasound between 26 and 36 weeks' gestation. Pregnancies with estimated fetal weight or abdominal circumference < 20 percentile with UA-PI measurements available were included.

View Article and Find Full Text PDF

Morphometry, variations, and histogenesis of umbilical vein, portal sinus, and ductus venosus in human fetal liver: an anatomical study.

Surg Radiol Anat

December 2024

Department of Anatomy, Kasturba Medical College, Manipal, Manipal Academy of Higher Education, Manipal, 576104, India.

Purpose: Anatomical research on fetal liver venous systems is scarce. This study presents variations, morphometric, and histogenesis data through cadaveric study which can aid prenatal radiological analysis.

Materials And Methods: 10% formalin embalmed 16 fetuses (8-second trimester, 8-third trimester) were utilized.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!