First observation of meridional focusing of an X-ray beam using diffraction by a crystal with a transverse groove.

J Synchrotron Radiat

Institute of Physics, Academy of Sciences of the Czech Republic, Na Slovance 2, 18221 Praha 8, Czech Republic.

Published: November 2001

The possibility of concentrating a synchrotron X-ray beam using diffraction by a single crystal with a properly designed transverse groove on its surface, suggested earlier, has been studied experimentally. Here, the first experimental demonstration of this effect is reported, performed on beamline BM5 at the ESRF. The experimental result confirms the theoretical model.

Download full-text PDF

Source
http://dx.doi.org/10.1107/s0909049501015163DOI Listing

Publication Analysis

Top Keywords

x-ray beam
8
beam diffraction
8
transverse groove
8
observation meridional
4
meridional focusing
4
focusing x-ray
4
diffraction crystal
4
crystal transverse
4
groove possibility
4
possibility concentrating
4

Similar Publications

This study assesses radiation doses in multi-slice computed tomography (CT) using epoxy resin and PMMA phantoms, focusing on the relationship between TAR (tissue air ratio) and kilovoltage peak (kVp). The research was conducted using a Hitachi Supria 16-slice CT scanner. An epoxy resin phantom was fabricated from commercially available materials, to simulate human tissue.

View Article and Find Full Text PDF

Deproteinized Bovine Bone Mineral With Collagen for Anterior Maxillary Ridge Augmentation: A Retrospective Cohort Study.

Clin Implant Dent Relat Res

February 2025

Department of Implantology, The Affiliated Hospital of Stomatology, School of Stomatology, Zhejiang University School of Medicine, Hangzhou, China.

Objectives: This study aimed to assess the effects of deproteinized bovine bone mineral with collagen (DBBMC) combined with deproteinized bovine bone mineral (DBBM) on facial alveolar bone augmentation in the anterior maxillary region.

Materials And Methods: Patients receiving dental implant placement with simultaneous lateral bone augmentation using DBBM (control group) or DBBMC combined with DBBM (test group) were included in the study. The radiographic assessment of facial alveolar bone, such as facial horizontal bone thickness (FHBT), facial vertical bone level (FVBL), and square of facial bone (SFB), was taken by cone beam computed tomography (CBCT).

View Article and Find Full Text PDF

For the purpose of assessing image quality and calculating patient X-ray dosage in radiology, computed tomography (CT), fluoroscopy, mammography, and other fields, it is necessary to have prior knowledge of the X-ray energy spectrum. The main components of an X-ray tube are an electron filament, also known as the cathode, and an anode, which is often made of tungsten or rubidium and angled at a certain angle. At the point where the electrons generated by the cathode and the anode make contact, a spectrum of X-rays with energies spanning from zero to the maximum energy value of the released electrons is created.

View Article and Find Full Text PDF

Simulations of the Potential for Diffraction Enhanced Imaging at 8 keV using Polycapillary Optics.

Biomed Phys Eng Express

January 2025

Physics Department, University at Albany, 1400 Washington Ave, Albany, New York, 12222-0100, UNITED STATES.

Conventional x-ray radiography relies on attenuation differences in the object, which often results in poor contrast in soft tissues. X-ray phase imaging has the potential to produce higher contrast but can be difficult to utilize. Instead of grating-based techniques, analyzer-based imaging, also known as diffraction enhanced imaging (DEI), uses a monochromator crystal with an analyzer crystal after the object.

View Article and Find Full Text PDF

Extreme ultraviolet (EUV) lithography is a cutting-edge technology in contemporary semiconductor chip manufacturing. Monitoring the EUV beam profiles is critical to ensuring consistent quality and precision in the manufacturing process. This study uncovers the practical use of fluorescent nanodiamonds (FNDs) coated on optical image sensors for profiling EUV and soft X-ray (SXR) radiation beams.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!